Verfasst von:Pathil-Warth, Anita [VerfasserIn]   i
 Stremmel, Wolfgang [VerfasserIn]   i
 Schwenger, Vedat [VerfasserIn]   i
 Eisenbach, Christoph [VerfasserIn]   i
Titel:The influence of haemodialysis on haemodynamic measurements using transpulmonary thermodilution in patients with septic shock
Titelzusatz:an observational study
Verf.angabe:Anita Pathil, Wolfgang Stremmel, Vedat Schwenger and Christoph Eisenbach
Jahr:2013
Umfang:5 S.
Fussnoten:Published online 29 August 2012 ; Gesehen am 20.12.2021
Titel Quelle:Enthalten in: European journal of anaesthesiology
Ort Quelle:Philadelphia, Pa. : Lippincott Williams & Wilkins, 1996
Jahr Quelle:2013
Band/Heft Quelle:30(2013), 1, Seite 16-20
ISSN Quelle:1365-2346
Abstract:Context: Patients with sepsis frequently present with acute renal failure requiring intermittent renal replacement therapy and haemodynamic monitoring. To date, the effect of haemodialysis on PiCCO monitoring has not been determined. - Objective: To determine the effect of haemodialysis on the measurement of haemodynamic variables using transpulmonary thermodilution. - Design: Prospective observational study. - Setting: Medical ICU in a university hospital. - Patients: Thirty patients with sepsis and acute renal failure undergoing intermittent haemodialysis. - Interventions: None. - Main outcome measures: Cardiac index, global end-diastolic volume index and extravascular lung water index measured with or without haemodialysis. - Results: Significant correlations were found for all variables measured with and without haemodialysis (r = 0.55 to 0.91, P < 0.01). Measurements of cardiac index without and with haemodialysis were significantly different [4.71 vs. 4.18 l min−1 m−2, difference −0.54 (SD 0.70), 95% confidence interval (CI) −0.80 to −0.28; P < 0.01], as were values of global end-diastolic volume index without and with haemodialysis [864.8 vs. 775.3 ml m−2, difference −89.5 (SD 191.8), 95% CI −161.2 to −17.9; P = 0.02]. Measurements of extravascular lung water index without and with haemodialysis did not differ significantly [10.3 vs. 10.0 ml kg−1, difference −0.3 (SD 2.0), 95% CI −1.1 to 0.5; P = 0.42]. - Conclusion: Although significant correlations were found for cardiac index, global end-diastolic volume index and extravascular lung water index with and without haemodialysis, cardiac index and global end-diastolic volume index were significantly reduced during haemodialysis, but not extravascular lung water index, when measured by the PiCCO system in patients with septic shock. Although differences were small, the variability of within-patient differences may be clinically important and care should be taken in relying solely on such measurements.
DOI:doi:10.1097/EJA.0b013e328358543a
URL:Bitte beachten Sie: Dies ist ein Bibliographieeintrag. Ein Volltextzugriff für Mitglieder der Universität besteht hier nur, falls für die entsprechende Zeitschrift/den entsprechenden Sammelband ein Abonnement besteht oder es sich um einen OpenAccess-Titel handelt.

Volltext ; Verlag: https://doi.org/10.1097/EJA.0b013e328358543a
 Volltext: https://journals.lww.com/ejanaesthesiology/Fulltext/2013/01000/The_influence_of_haemodialysis_on_haemodynamic.5.aspx
 DOI: https://doi.org/10.1097/EJA.0b013e328358543a
Datenträger:Online-Ressource
Sprache:eng
K10plus-PPN:1782586296
Verknüpfungen:→ Zeitschrift

Permanenter Link auf diesen Titel (bookmarkfähig):  https://katalog.ub.uni-heidelberg.de/titel/68845881   QR-Code
zum Seitenanfang