Status: Bibliographieeintrag
Standort: ---
Exemplare:
---
| Online-Ressource |
Titel: | Intraoperative lung edema monitoring by microwave reflectometry |
Mitwirkende: | Nowak, Kai  |
| Gross, Wolfgang  |
| Nicksch, Kathrin  |
| Dacho, Christine  |
| Helbig, Marko  |
| Hohenberger, Peter  |
| Gebhard, Martha-Maria  |
| Schäfer, Michael  |
Verf.angabe: | Kai Nowak; Wolfgang Gross; Kathrin Nicksch; Christine Hanusch; Marko Helbig; Peter Hohenberger; Martha M. Gebhard; Michael Schaefer |
Jahr: | 2011 |
Umfang: | 5 S. |
Titel Quelle: | In: Interactive cardiovascular and thoracic surgery |
Ort Quelle: | Oxford : Oxford Univ. Press, 2002 |
Jahr Quelle: | 2011 |
Band/Heft Quelle: | 12(2011), 4, Seite 540-544 |
ISSN Quelle: | 1569-9285 |
Abstract: | Microwave reflectometry might be a suitable tool for the thoracic surgeon to monitor edema formation of the lung during lung surgery. A new setup of microwave reflectometry for lung water measurements was developed and tested for clinical application. Three lung models were used for the microwave reflectometry tests: 1) the model of an ex vivo isolated perfused rat lung to investigate lung edema formation during ischemia-reperfusion (n=6), 2) the in situ lung of a human patient to demonstrate the feasibility of lung water monitoring during a surgical operation, 3) the model of an ex vivo isolated perfused human lung to investigate edema formation during postischemic reperfusion and to investigate the changes in water content in the region of a tumor. During human lung operation, significant changes in water content occurred in different lung areas. During isolated perfusion, a significant increase in lung water was measured in models 1) and 3) (P=0.03). Water content of tumor tissue was higher than in the surrounding healthy lung tissue. Microwave reflectometry offers a noninvasive approach to monitor lung edema formation in experimental models and during thoracic surgery. |
DOI: | doi:10.1510/icvts.2010.243691 |
URL: | Bitte beachten Sie: Dies ist ein Bibliographieeintrag. Ein Volltextzugriff für Mitglieder der Universität besteht hier nur, falls für die entsprechende Zeitschrift/den entsprechenden Sammelband ein Abonnement besteht oder es sich um einen OpenAccess-Titel handelt.
kostenfrei: Volltext: https://doi.org/10.1510/icvts.2010.243691 |
| DOI: https://doi.org/10.1510/icvts.2010.243691 |
Datenträger: | Online-Ressource |
Sprache: | eng |
Bibliogr. Hinweis: | Erscheint auch als : Druck-Ausgabe: Intraoperative lung edema monitoring by microwave reflectometry. - 2011 |
K10plus-PPN: | 683328778 |
Verknüpfungen: | → Zeitschrift |
Intraoperative lung edema monitoring by microwave reflectometry / Nowak, Kai; 2011 (Online-Ressource)
68862206