Navigation überspringen
Universitätsbibliothek Heidelberg
Status: Bibliographieeintrag

Verfügbarkeit
Standort: ---
Exemplare: ---
heiBIB
 Online-Ressource
Verfasst von:Rillig, Andreas [VerfasserIn]   i
 Schmidt, Boris [VerfasserIn]   i
 Steven, Daniel [VerfasserIn]   i
 Meyerfeldt, Udo [VerfasserIn]   i
 Di Biase, Luigi [VerfasserIn]   i
 Wissner, Erik [VerfasserIn]   i
 Becker, Rüdiger [VerfasserIn]   i
 Thomas, Dierk [VerfasserIn]   i
 Wohlmuth, Peter [VerfasserIn]   i
 Gallinghouse, G. Joseph [VerfasserIn]   i
 Scholz, Eberhard P. [VerfasserIn]   i
 Jung, Werner [VerfasserIn]   i
 Willems, Stefan [VerfasserIn]   i
 Natale, Andrea [VerfasserIn]   i
 Ouyang, Feifan [VerfasserIn]   i
 Kuck, Karl Heinz [VerfasserIn]   i
 Tilz, Roland [VerfasserIn]   i
Titel:Study design of the man and machine trial
Titelzusatz:a prospective international controlled noninferiority trial comparing manual with robotic catheter ablation for treatment of atrial fibrillation
Verf.angabe:Andreas Rillig, Boris Schmidt, Daniel Steven, Udo Meyerfeldt, Luigi Di Biase, Erik Wissner, Rüdiger Becker, Dierk Thomas, Peter Wohlmuth, G. Joseph Gallinghouse, Eberhardt Scholz, Werner Jung, Stefan Willems, Andrea Natale, Feifan Ouyang, Karl Heinz Kuck, and Roland Tilz
Jahr:2013
Umfang:7 S.
Fussnoten:First published: 25 July 2012 ; Gesehen am 01.02.2022
Titel Quelle:Enthalten in: Journal of cardiovascular electrophysiology
Ort Quelle:Oxford : Wiley-Blackwell, 1990
Jahr Quelle:2013
Band/Heft Quelle:24(2013), 1 vom: Jan., Seite 40-46
ISSN Quelle:1540-8167
Abstract:Study Design of the Man and Machine Trial. Background: Pulmonary vein isolation (PVI) has become the cornerstone procedure for the treatment of symptomatic drug-resistant atrial fibrillation (AF). At the present time, circumferential PVI (CPVI) using irrigated radiofrequency (RF) is the mostly used ablation technique. However, for CPVI, precise catheter navigation and excellent catheter stability is crucial thereby requiring experienced operators. Robotic navigation systems have been introduced to facilitate catheter navigation and to improve catheter stability, therefore potentially increasing procedural success and making CPVI accessible to less experienced operators. To date, no prospective randomized trial has evaluated the efficacy and safety of CPVI using RNS compared to manually performed ablation. Methods: In this prospective international multicenter noninferiority trial, 258 patients with either paroxysmal or short-standing persistent AF will be randomized for comparison of PVI using either manual or robotic ablation. In all patients, CPVI will be performed using irrigated RF ablation in combination with a 3D mapping system. The primary endpoint of the trial is the absence of AF or atrial tachycardia without antiarrhythmic drug therapy during 12-month follow-up. Secondary endpoints will be evaluation of periprocedural complications and procedural data such as procedure time, fluoroscopy time, as well as the incidence of esophageal injury assessed by endoscopy within 48 hours after the procedure. Conclusion: The “Man and Machine Trial” is the first prospective international randomized controlled multicenter noninferiority trial to compare manually performed CPVI with robotically navigated CPVI, evaluating both the safety and efficacy of the 2 techniques during a 12-month follow-up period. (J Cardiovasc Electrophysiol, Vol. 24, pp. 40-46, January 2013)
DOI:doi:10.1111/j.1540-8167.2012.02418.x
URL:Bitte beachten Sie: Dies ist ein Bibliographieeintrag. Ein Volltextzugriff für Mitglieder der Universität besteht hier nur, falls für die entsprechende Zeitschrift/den entsprechenden Sammelband ein Abonnement besteht oder es sich um einen OpenAccess-Titel handelt.

Volltext ; Verlag: https://doi.org/10.1111/j.1540-8167.2012.02418.x
 Volltext: https://onlinelibrary.wiley.com/doi/abs/10.1111/j.1540-8167.2012.02418.x
 DOI: https://doi.org/10.1111/j.1540-8167.2012.02418.x
Datenträger:Online-Ressource
Sprache:eng
Sach-SW:atrial fibrillation
 catheter ablation
 pulmonary vein isolation
 randomized clinical trial
 robotics
K10plus-PPN:1787967735
Verknüpfungen:→ Zeitschrift

Permanenter Link auf diesen Titel (bookmarkfähig):  https://katalog.ub.uni-heidelberg.de/titel/68872837   QR-Code
zum Seitenanfang