Titel:Noise-robust breathing-phase estimation on marker-free, ultra low dose X-ray projections for real-time tumor localization via surrogate structures
Verf.angabe:Max F. W. Dellmann, Katharina I. Jerg, Johanna Stratemeier, Ron Heiman, Jürgen W. Hesser, Katharina P. Aschenbrenner, Manuel Blessing
E-Jahr:2021
Jahr:2 June 2021
Umfang:10 S.
Fussnoten:Gesehen am 08.02.2022
Titel Quelle:Enthalten in: Zeitschrift für medizinische Physik
Ort Quelle:Amsterdam [u.a.] : Elsevier, 1990
Jahr Quelle:2021
Band/Heft Quelle:31(2021), 4, Seite 355-364
ISSN Quelle:1876-4436
Abstract:Purpose - This paper presents a novel strategy for feature-based breathing-phase estimation on ultra low-dose X-ray projections for tumor motion control in radiation therapy. - Methods - Coarse-scaled Curvelet coefficients are identified as motion sensitive but noise-robust features for this purpose. For feature-based breathing-phase estimation, an ensemble strategy with two classifiers is used. This consensus-based estimation substantially increases tracking reliability by rejection of false positives. The algorithm is evaluated on both synthetic and measured phantom data: Monte Carlo simulated ultra low dose projections for a C-arm X-ray and on the basis of 4D-chest-CTs of eight patients on one hand side and real measurements based on a motion phantom. - Results - To achieve an accuracy of breathing-phase estimation of more than 95% a fluence between 20 and 400 photons per pixel (open field) is required depending on the patient. Furthermore, the algorithm is evaluated on real ultra low dose projections from an XVI R5.0 system (Elekta AB, Stockholm, Sweden) using an additional lead filter to reduce fluence. The classifiers-consensus-based-gating method estimated the correct position of the test projections in all test cases at a fluence of ∼180 photons per pixel and 92% at a fluence of ∼40 photons per pixel. The deposited dose to patient per image is in the range of nGy. - Conclusions - A novel method is presented for estimation of breathing-phases for real-time tumor localization at ultra low dose both on a simulation and a phantom basis. Its accuracy is comparable to state of the art X-ray based algorithms while the released dose to patients is reduced by two to three orders of magnitude compared to conventional template-based approaches. This allows for continuous motion control during irradiation without the need of external markers.
DOI:doi:10.1016/j.zemedi.2021.04.001
URL:Bitte beachten Sie: Dies ist ein Bibliographieeintrag. Ein Volltextzugriff für Mitglieder der Universität besteht hier nur, falls für die entsprechende Zeitschrift/den entsprechenden Sammelband ein Abonnement besteht oder es sich um einen OpenAccess-Titel handelt.

Volltext: https://doi.org/10.1016/j.zemedi.2021.04.001
 Volltext: https://www.sciencedirect.com/science/article/pii/S0939388921000350
 DOI: https://doi.org/10.1016/j.zemedi.2021.04.001
Datenträger:Online-Ressource
Sprache:eng
Sach-SW:Breathing-phase estimation
 Classifiers-consensus
 Curvelet coefficients
 Tumor-tracking