Titel: | Triple channel analysis of Gafchromic EBT3 irradiated with clinical carbon-ion beams |
Verf.angabe: | Kim Marina Holm, Eduardo G. Yukihara, Md Foiez Ahmed, Steffen Greilich, Oliver Jäkel |
E-Jahr: | 2021 |
Jahr: | July 2021 |
Umfang: | 8 S. |
Fussnoten: | Available online 16 June 2021, version of record 16 June 2021 |
Titel Quelle: | Enthalten in: Physica medica |
Ort Quelle: | Amsterdam : Elsevier, 1996 |
Jahr Quelle: | 2021 |
Band/Heft Quelle: | 87(2021), Seite 123-130 |
ISSN Quelle: | 1724-191X |
Abstract: | Self-developing radiochromic film is widely used in radiotherapy QA procedures. To compensate for typical film inhomogeneities, the triple channel analysis method is commonly used for photon-irradiated film. We investigated the applicability of this method for GafchromicTMEBT3 (Ashland) film irradiated with a clinically used carbon-ion beam. Calibration curves were taken from EBT3 film specimens irradiated with monoenergetic carbon-ion beams of different doses. Measurements of the lateral field shape and homogeneity were performed in the middle of a passively modulated spread-out Bragg peak and compared to simultaneous characterization by means of a 2D ionization chamber array. Additional measurements to investigate the applicability of EBT3 for quality assurance (QA) measurement in carbon-ion beams were performed. The triple-channel analysis reduced the relative standard deviation of the doses in a uniform carbon ion field by 30% (from 1.9% to 1.3%) and reduced the maximum deviation by almost a factor of 3 (from 28.6% to 9.8%), demonstrating the elimination of film artifacts. The corrected film signal showed considerably improved image quality and quantitative agreement with the ionization chamber data, thus providing a clear rationale for the usage of the triple channel analysis in carbon-beam QA. |
DOI: | doi:10.1016/j.ejmp.2021.06.009 |
URL: | Bitte beachten Sie: Dies ist ein Bibliographieeintrag. Ein Volltextzugriff für Mitglieder der Universität besteht hier nur, falls für die entsprechende Zeitschrift/den entsprechenden Sammelband ein Abonnement besteht oder es sich um einen OpenAccess-Titel handelt.
Volltext ; Verlag: https://doi.org/10.1016/j.ejmp.2021.06.009 |
| Volltext: https://www.sciencedirect.com/science/article/pii/S1120179721002295 |
| DOI: https://doi.org/10.1016/j.ejmp.2021.06.009 |
Datenträger: | Online-Ressource |
Sprache: | eng |
Sach-SW: | Carbon-ion beams |
| Gafchromic EBT3 |
| Triple channel analysis |
K10plus-PPN: | 1790050278 |
Verknüpfungen: | → Zeitschrift |
Triple channel analysis of Gafchromic EBT3 irradiated with clinical carbon-ion beams / Holm, Kim Marina [VerfasserIn]; July 2021 (Online-Ressource)
68880306