Navigation überspringen
Universitätsbibliothek Heidelberg
Standort: ---
Exemplare: ---
heiBIB
 Online-Ressource
Verfasst von:Fink, Matthias A. [VerfasserIn]   i
 Hartmann, Sibylle [VerfasserIn]   i
 Melzig, Claudius [VerfasserIn]   i
 Steuwe, Andrea [VerfasserIn]   i
 Partovi, Sasan [VerfasserIn]   i
 Böckler, Dittmar [VerfasserIn]   i
 Kauczor, Hans-Ulrich [VerfasserIn]   i
 Rengier, Fabian [VerfasserIn]   i
Titel:Prospective study of low-radiation and low-iodine dose aortic CT angiography in obese and non-obese patients
Titelzusatz:image quality and impact of patient characteristics
Verf.angabe:Matthias A. Fink, Sibylle Stoll, Claudius Melzig, Andrea Steuwe, Sasan Partovi, Dittmar Böckler, Hans-Ulrich Kauczor and Fabian Rengier
E-Jahr:2022
Jahr:10 March 2022
Umfang:13 S.
Fussnoten:Gesehen am 05.04.2022
Titel Quelle:Enthalten in: Diagnostics
Ort Quelle:Basel : MDPI, 2011
Jahr Quelle:2022
Band/Heft Quelle:12(2022), 3, Artikel-ID 675, Seite 1-13
ISSN Quelle:2075-4418
Abstract:The purpose of this study was to prospectively analyse image quality and radiation dose of body mass index (BMI)-adapted low-radiation and low-iodine dose CTA of the thoracoabdominal aorta in obese and non-obese patients. This prospective, single-centre study included patients scheduled for aortic CTA between November 2017 and August 2020 without symptoms of high-grade heart failure. A BMI-adapted protocol was used: Group A/Group B, BMI < 30/≥ 30 kg/m2, tube potential 80/100 kVp, total iodine dose 14.5/17.4 g. Intraindividual comparison with the institutional clinical routine aortic CTA protocol was performed. The final study cohort comprised 161 patients (mean 71.1 ± 9.4 years, 32 women), thereof 126 patients in Group A (mean BMI 25.4 ± 2.8 kg/m2) and 35 patients in Group B (34.0 ± 3.4 kg/m2). Mean attenuation over five aortoiliac measurement positions for Group A/B was 354.9 ± 78.2/262.1 ± 73.0 HU. Mean effective dose for Group A/B was 3.05 ± 0.46/6.02 ± 1.14 mSv. Intraindividual comparison in 50 patients demonstrated effective dose savings for Group A/B of 34.4 ± 14.5/25.4 ± 14.1% (both p < 0.001), and iodine dose savings for Group A/B of 54/44.8%. Regression analysis showed that female sex and increasing age were independently associated with higher vascular attenuation. In conclusion, BMI-adapted, low-radiation and low-iodine dose CTA of the thoracoabdominal aorta delivers diagnostic image quality in non-obese and obese patients without symptoms of high-grade heart failure, with superior image quality in females and the elderly.
DOI:doi:10.3390/diagnostics12030675
URL:kostenfrei: Volltext: https://doi.org/10.3390/diagnostics12030675
 kostenfrei: Volltext: https://www.mdpi.com/2075-4418/12/3/675
 DOI: https://doi.org/10.3390/diagnostics12030675
Datenträger:Online-Ressource
Sprache:eng
Sach-SW:aorta
 computed tomography angiography
 contrast media
 obesity
 radiation dosage
K10plus-PPN:1797633872
Verknüpfungen:→ Zeitschrift
 
 
Lokale URL UB: Zum Volltext

Permanenter Link auf diesen Titel (bookmarkfähig):  https://katalog.ub.uni-heidelberg.de/titel/68903794   QR-Code
zum Seitenanfang