Navigation überspringen
Universitätsbibliothek Heidelberg
Status: Bibliographieeintrag

Verfügbarkeit
Standort: ---
Exemplare: ---
heiBIB
 Online-Ressource
Verfasst von:Alonso, Angelika [VerfasserIn]   i
 Della Martina, Alberto [VerfasserIn]   i
 Stroick, Mark Gregor [VerfasserIn]   i
 Fatar, Marc [VerfasserIn]   i
 Griebe, Martin [VerfasserIn]   i
 Pochon, Sibylle [VerfasserIn]   i
 Schneider, Michel [VerfasserIn]   i
 Hennerici, Michael G. [VerfasserIn]   i
 Allémann, Eric [VerfasserIn]   i
 Meairs, Stephen [VerfasserIn]   i
Titel:Molecular imaging of human thrombus with novel abciximab immunobubbles and ultrasound
Verf.angabe:Angelika Alonso, Alberto Della Martina, Mark Stroick, Marc Fatar, Martin Griebe, Sibylle Pochon, Michel Schneider, Michael Hennerici, Eric Allémann, and Stephen Meairs
E-Jahr:2007
Jahr:22 March 2007
Umfang:7 S.
Fussnoten:Gesehen am 04.05.2022
Titel Quelle:Enthalten in: Stroke
Ort Quelle:New York, NY : Association, 1970
Jahr Quelle:2007
Band/Heft Quelle:38(2007), 5, Seite 1508-1514
ISSN Quelle:1524-4628
Abstract:BACKGROUND AND PURPOSE: Molecular imaging of therapeutic interventions with targeted agents that simultaneously carry drugs or genes for local delivery is appealing. We investigated the ability of a novel microbubble carrier (immunobubble) for abciximab, a glycoprotein IIb/IIIa receptor inhibitor, for ultrasonographic molecular imaging of human clots. - METHODS: Human thrombi were incubated with immunobubbles conjugated with abciximab. Control clots were incubated in either saline or with immunobubbles conjugated with nonspecific antibody. We evaluated immunobubble suspensions with variable concentrations of encapsulated gas and measured mean acoustic intensity of the incubated clots. In vivo molecular imaging of human thrombi with abciximab immunobubbles was evaluated in a rat model of carotid artery occlusion. - RESULTS: Mean acoustic intensity was significantly higher for abciximab immunobubbles as compared with control immunobubbles under all conditions tested with maximum difference in intensity at a gas volume of 0.2 microL (P=0.0013 for mechanical index 0.05, P=0.0001 for mechanical index 0.7). Binding of abciximab immunobubbles to clots in vitro led to enhanced echogenicity dependent on bubble concentration. In vivo ultrasonic detectability of carotid thrombi was significantly higher for clots targeted with abciximab immunobubbles (P<0.05). Quantification of in vivo contrast enhancement displayed a highly significant increment for abciximab immunobubble-targeted clots compared with nonspecific immunobubble-targeted clots (P<0.0001) and to native clots (P<0.0001). - CONCLUSIONS: This study demonstrates the feasibility of using a therapeutic agent for selective targeting in vascular imaging. Abciximab immunobubbles improve visualization of human clots both in vitro and in an in vivo model of acute arterial thrombotic occlusion.
DOI:doi:10.1161/STROKEAHA.106.471391
URL:Bitte beachten Sie: Dies ist ein Bibliographieeintrag. Ein Volltextzugriff für Mitglieder der Universität besteht hier nur, falls für die entsprechende Zeitschrift/den entsprechenden Sammelband ein Abonnement besteht oder es sich um einen OpenAccess-Titel handelt.

Volltext: https://doi.org/10.1161/STROKEAHA.106.471391
 DOI: https://doi.org/10.1161/STROKEAHA.106.471391
Datenträger:Online-Ressource
Sprache:eng
Sach-SW:Abciximab
 Animals
 Antibodies, Monoclonal
 Disease Models, Animal
 Feasibility Studies
 Humans
 Immunoglobulin Fab Fragments
 In Vitro Techniques
 Microbubbles
 Platelet Aggregation Inhibitors
 Rats
 Rats, Wistar
 Thrombosis
 Ultrasonography
K10plus-PPN:1800864248
Verknüpfungen:→ Zeitschrift

Permanenter Link auf diesen Titel (bookmarkfähig):  https://katalog.ub.uni-heidelberg.de/titel/68914574   QR-Code
zum Seitenanfang