Navigation überspringen
Universitätsbibliothek Heidelberg
Status: Bibliographieeintrag

Verfügbarkeit
Standort: ---
Exemplare: ---
heiBIB
 Online-Ressource
Verfasst von:Jakubowitz, Eike [VerfasserIn]   i
 Kinkel, Stefan [VerfasserIn]   i
 Nadorf, Jan [VerfasserIn]   i
 Heisel, Jens Christian [VerfasserIn]   i
 Kretzer, Jan Philippe [VerfasserIn]   i
 Thomsen, Marc N. [VerfasserIn]   i
Titel:The effect of multifilaments and monofilaments on cementless femoral revision hip components
Titelzusatz:An experimental study
Verf.angabe:Eike Jakubowitz, Stefan Kinkel, Jan Nadorf, Christian Heisel, J. Philippe Kretzer, Marc N. Thomsen
Jahr:2011
Umfang:5 S.
Fussnoten:Available online 13 December 2010 ; Gesehen am 04.07.2022
Titel Quelle:Enthalten in: Clinical biomechanics
Ort Quelle:Amsterdam [u.a.] : Elsevier Science, 1986
Jahr Quelle:2011
Band/Heft Quelle:26(2011), 3, Seite 257-261
ISSN Quelle:1879-1271
Abstract:Background - Cerclage wires are widely used in revision hip surgery to reattach the lid of a femoral osteotomy. The present study compared the influence of multifilaments and monofilaments on primary stability of revision hip stems with different fixation principles. - Methods - A standardized extended proximal femoral osteotomy was performed in the anterior cortex of 6 synthetic femora. We used a high-resolution measuring device to explore spatial micromovements of a diaphyseal and a metaphyseal fixating revision stem. Both of these were implanted in 3 femora. The specimens were measured again after consecutive restabilization of osteotomies with multifilaments and monofilaments. The movement graphs generated defined relative micromovements between stems and bones and the stabilizing effect of the two wire systems compared. - Findings - Both multifilaments and monofilaments effected a major reduction of relative micromovements for both fixation principles. There were no differences in relative movements between the multifilament and monofilament treatments for the diaphyseal fixating stem. Yet for the metaphyseal fixating stem a significantly better restabilization was observed with multifilaments. - Interpretation - Both multifilaments and monofilaments can support the revision hip stem in bridging the extended proximal femoral osteotomy. Yet, which wiring system should be chosen depends on the fixation principle of the revision stem. Multifilaments seem to be advantageous when used with metaphyseal fixating stems. However, the use of multifilaments with diaphyseal fixating components should be reconsidered as this might constrict the periosteal vascularity.
DOI:doi:10.1016/j.clinbiomech.2010.11.004
URL:Bitte beachten Sie: Dies ist ein Bibliographieeintrag. Ein Volltextzugriff für Mitglieder der Universität besteht hier nur, falls für die entsprechende Zeitschrift/den entsprechenden Sammelband ein Abonnement besteht oder es sich um einen OpenAccess-Titel handelt.

Volltext ; Verlag: https://doi.org/10.1016/j.clinbiomech.2010.11.004
 Volltext: https://www.sciencedirect.com/science/article/pii/S0268003310002986
 DOI: https://doi.org/10.1016/j.clinbiomech.2010.11.004
Datenträger:Online-Ressource
Sprache:eng
Sach-SW:Cable
 Cerclage
 Femoral osteotomy
 Osteosynthesis
 Revision hip surgery
K10plus-PPN:1809033861
Verknüpfungen:→ Zeitschrift

Permanenter Link auf diesen Titel (bookmarkfähig):  https://katalog.ub.uni-heidelberg.de/titel/68937075   QR-Code
zum Seitenanfang