| Online-Ressource |
Verfasst von: | Tavakoli, Andrej [VerfasserIn]  |
| Dreher, Constantin [VerfasserIn]  |
| Młynarska-Bujny, Anna [VerfasserIn]  |
| Kuder, Tristan Anselm [VerfasserIn]  |
| Gnirs, Regula [VerfasserIn]  |
| Schlemmer, Heinz-Peter [VerfasserIn]  |
| Bickelhaupt, Sebastian [VerfasserIn]  |
Titel: | Pancreatic imaging using diffusivity mapping - Influence of sequence technique on qualitative and quantitative analysis |
Verf.angabe: | Anoshirwan Andrej Tavakoli, Constantin Dreher, Anna Mlynarska, Tristan Anselm Kuder, Regula Gnirs, Heinz-Peter Schlemmer, Sebastian Bickelhaupt |
Jahr: | 2022 |
Umfang: | 8 S. |
Fussnoten: | Available online 10 December 2021 ; Gesehen am 30.08.2022 |
Titel Quelle: | Enthalten in: Clinical imaging |
Ort Quelle: | Amsterdam [u.a.] : Elsevier Science, 1989 |
Jahr Quelle: | 2022 |
Band/Heft Quelle: | 83(2022), Seite 33-40 |
ISSN Quelle: | 1873-4499 |
Abstract: | PURPOSE: To compare image quality of an optimized diffusion weighted imaging (DWI) sequence with advanced post-processing and motion correction (advanced-EPI) to a standard DWI protocol (standard-EPI) in pancreatic imaging. - MATERIALS AND METHODS: 62 consecutive patients underwent abdominal MRI at 1.5 T were included in this retrospective analysis of data collected as part of an IRB approved study. All patients received a standard-EPI and an advanced-EPI DWI with advanced post-processing and motion correction. Two blinded radiologists evaluated the parameters image quality, detail of parenchyma, sharpness of boundaries and discernibility from adjacent structures on b = 900 s/mm2 images using a Likert-like scale. Segmentation of pancreatic head, body and tail were obtained and apparent diffusion coefficient (ADC) was calculated separately for each region. Apparent tissue-to-background ratio (TBR) was calculated at b = 50 s/mm2 and at b = 900 s/mm2. - RESULTS: The advanced-EPI yielded significantly higher scores for pancreatic parameters of image quality, detail level of parenchyma, sharpness of boundaries and discernibility from adjacent structures in comparison to standard-EPI (p < 0.001 for all, kappa = [0.46,0.71]) and was preferred in 96% of the cases when directly compared. ADC of the pancreas was 7% lower in advanced-EPI (1.236 ± 0.152 vs. 1.146 ± 0.126 μm2/ms, p < 0.001). ADC in the pancreatic tail was significantly lower for both sequences compared to head and body (all p < 0.001). There was comparable TBR for both sequences at b = 50 s/mm2 (standard-EPI: 19.0 ± 5.9 vs. advanced-EPI: 19.0 ± 6.4, p = 0.96), whereas at b = 900 s/mm2, TBR was 51% higher for advanced-EPI (standard-EPI: 7.1 ± 2.5 vs. advanced-EPI: 10.8 ± 5.1, p < 0.001). - CONCLUSION: An advanced DWI sequence might increase image quality for focused imaging of the pancreas and providing improved parenchymal detail levels compared to a standard DWI. |
DOI: | doi:10.1016/j.clinimag.2021.11.033 |
URL: | Bitte beachten Sie: Dies ist ein Bibliographieeintrag. Ein Volltextzugriff für Mitglieder der Universität besteht hier nur, falls für die entsprechende Zeitschrift/den entsprechenden Sammelband ein Abonnement besteht oder es sich um einen OpenAccess-Titel handelt.
Volltext: https://doi.org/10.1016/j.clinimag.2021.11.033 |
| DOI: https://doi.org/10.1016/j.clinimag.2021.11.033 |
Datenträger: | Online-Ressource |
Sprache: | eng |
Sach-SW: | Artifacts |
| Diffusion magnetic resonance imaging |
| Diffusion Magnetic Resonance Imaging |
| Echo-planar imaging |
| Echo-Planar Imaging |
| Humans |
| Magnetic resonance imaging |
| Pancreas |
| Reproducibility of Results |
| Retrospective Studies |
K10plus-PPN: | 1815401028 |
Verknüpfungen: | → Zeitschrift |
Pancreatic imaging using diffusivity mapping - Influence of sequence technique on qualitative and quantitative analysis / Tavakoli, Andrej [VerfasserIn]; 2022 (Online-Ressource)