Navigation überspringen
Universitätsbibliothek Heidelberg
Status: Bibliographieeintrag

Verfügbarkeit
Standort: ---
Exemplare: ---

+ Andere Auflagen/Ausgaben
heiBIB
 Online-Ressource
Verfasst von:Sommer, Christof-Matthias [VerfasserIn]   i
 Koch, Vitali [VerfasserIn]   i
 Pap, Bence [VerfasserIn]   i
 Bellemann, Nadine [VerfasserIn]   i
 Holzschuh, Maria [VerfasserIn]   i
 Gehrig, Tobias [VerfasserIn]   i
 Shevchenko, Maxym [VerfasserIn]   i
 Arnegger, Florian U. [VerfasserIn]   i
 Nickel, Felix [VerfasserIn]   i
 Mogler, Carolin [VerfasserIn]   i
 Zelzer, Sascha [VerfasserIn]   i
 Meinzer, Hans-Peter [VerfasserIn]   i
 Stampfl, Ulrike [VerfasserIn]   i
 Kauczor, Hans-Ulrich [VerfasserIn]   i
 Radeleff, Boris [VerfasserIn]   i
Titel:Effect of tissue perfusion on microwave ablation
Titelzusatz:experimental in vivo study in porcine kidneys
Verf.angabe:Christof M. Sommer, Vitali Koch, Bence Pap, Nadine Bellemann, Maria Holzschuh, Tobias Gehrig, Maxym Shevchenko, Florian U. Arnegger, Felix Nickel, Carolin Mogler, Sascha Zelzer, Hans P. Meinzer, Ulrike Stampfl, Hans U. Kauczor, Boris A. Radeleff
E-Jahr:2011
Jahr:6 October 2011
Umfang:7 S.
Fussnoten:Gesehen am 18.10.2022
Titel Quelle:Enthalten in: Journal of vascular and interventional radiology
Ort Quelle:Amsterdam [u.a.] : Elsevier, 1990
Jahr Quelle:2011
Band/Heft Quelle:22(2011), 12, Seite 1751-1757
ISSN Quelle:1535-7732
Abstract:Purpose - To determine the effect of tissue perfusion on microwave ablation lesions in an experimental in vivo study in porcine kidneys. - Materials and Methods - Twelve kidneys of six pigs were studied. In each animal, two microwave ablations were created in one kidney without limitation of tissue perfusion (group 1). In the other kidney, two microwave ablations were performed with interruption of blood flow (group 2). All microwave ablations were performed with identical system parameters (eg, temperature control mode, ablation time of 80 s, and temperature of 110°C). The animals were euthanized 3 hours later. The kidneys were harvested and cut into 2-3-mm transverse slices. Microwave ablation zone dimensions (eg, length, width, and volume) and shape (eg, sphericity ratio) and corresponding variability were compared between groups. - Results - Microwave ablation areas were significantly longer (41.6 mm ± 4.0 vs 34.2 mm ± 5.9; P < .01) and wider (16.6 mm ± 1.2 vs 12.2 mm ± 2.1; P < .001) in group 2 than in group 1. Similarly, microwave ablation volume was significantly greater in group 2 compared with group 1 (6.7 cm3 ± 1.0 vs 3.3 cm3 ± 1.2; P < .001). Ablation area shapes were similar between groups (sphericity ratio, 2.57 ± 0.42 vs 2.39 ± 0.34). Ablation area variabilities were also comparable between groups (volume variance of 1.32 vs 0.93; sphericity ratio variance of 0.18 vs 0.11). - Conclusions - After interruption of blood flow, microwave ablation areas are significantly larger than those achieved without limitation of tissue perfusion. Microwave ablation area shape and variability were comparable between study groups.
DOI:doi:10.1016/j.jvir.2011.07.020
URL:Bitte beachten Sie: Dies ist ein Bibliographieeintrag. Ein Volltextzugriff für Mitglieder der Universität besteht hier nur, falls für die entsprechende Zeitschrift/den entsprechenden Sammelband ein Abonnement besteht oder es sich um einen OpenAccess-Titel handelt.

Volltext ; Verlag: https://doi.org/10.1016/j.jvir.2011.07.020
 Volltext: https://www.sciencedirect.com/science/article/pii/S1051044311011699
 DOI: https://doi.org/10.1016/j.jvir.2011.07.020
Datenträger:Online-Ressource
Sprache:eng
Bibliogr. Hinweis:Erscheint auch als : Druck-Ausgabe: Effect of tissue perfusion on microwave ablation. - 2011
K10plus-PPN:1819120198
Verknüpfungen:→ Zeitschrift

Permanenter Link auf diesen Titel (bookmarkfähig):  https://katalog.ub.uni-heidelberg.de/titel/68975477   QR-Code
zum Seitenanfang