Titel:Drift time measurement in the ATLAS liquid argon electromagnetic calorimeter using cosmic muons
Körperschaft:ATLAS Collaboration [VerfasserIn]   i
Verf.angabe:The ATLAS Collaboration*
E-Jahr:2010
Jahr:23 October 2010
Umfang:31 S.
Fussnoten:*The ATLAS Collaboration: G. Aad, V. Andrei, T.A. Dietzsch, P. Hanke, A. Khomich, E.-E. Kluge, A. Kugel, R. Maenner, K. Meier, F. Mueller, S. Poddar, V. Radescu, S. Schaetzel, H.-C. Schultz-Coulon, R. Stamen, M. Wessels [und sehr viele weitere Personen] ; Gesehen am 31.10.2022
Titel Quelle:Enthalten in: The European physical journal / C
Ort Quelle:Berlin : Springer, 1998
Jahr Quelle:2010
Band/Heft Quelle:70(2010), Seite 755-785
ISSN Quelle:1434-6052
Abstract:The ionization signals in the liquid argon of the ATLAS electromagnetic calorimeter are studied in detail using cosmic muons. In particular, the drift time of the ionization electrons is measured and used to assess the intrinsic uniformity of the calorimeter gaps and estimate its impact on the constant term of the energy resolution. The drift times of electrons in the cells of the second layer of the calorimeter are uniform at the level of 1.3% in the barrel and 2.8% in the endcaps. This leads to an estimated contribution to the constant term of $(0.29^{+0.05}_{-0.04})$% in the barrel and $(0.54^{+0.06}_{-0.04})$% in the endcaps. The same data are used to measure the drift velocity of ionization electrons in liquid argon, which is found to be 4.61±0.07 mm/μs at 88.5 K and 1 kV/mm.
DOI:doi:10.1140/epjc/s10052-010-1403-6
URL:Bitte beachten Sie: Dies ist ein Bibliographieeintrag. Ein Volltextzugriff für Mitglieder der Universität besteht hier nur, falls für die entsprechende Zeitschrift/den entsprechenden Sammelband ein Abonnement besteht oder es sich um einen OpenAccess-Titel handelt.

Volltext: https://doi.org/10.1140/epjc/s10052-010-1403-6
 DOI: https://doi.org/10.1140/epjc/s10052-010-1403-6