Navigation überspringen
Universitätsbibliothek Heidelberg
Status: Bibliographieeintrag

Verfügbarkeit
Standort: ---
Exemplare: ---
heiBIB
 Online-Ressource
Verfasst von:Pfäfflein, Philip [VerfasserIn]   i
 Allgeier, Steffen [VerfasserIn]   i
 Bernitt, Sonja [VerfasserIn]   i
 Fleischmann, Andreas [VerfasserIn]   i
 Friedrich, M. [VerfasserIn]   i
 Hahn, Christoph [VerfasserIn]   i
 Hengstler, Daniel [VerfasserIn]   i
 Herdrich, Marc Oliver [VerfasserIn]   i
 Kalinin, A. [VerfasserIn]   i
 Kröger, Felix Martin [VerfasserIn]   i
 Kuntz, P. [VerfasserIn]   i
 Lestinsky, Michael [VerfasserIn]   i
 Löher, B. [VerfasserIn]   i
 Menz, E. B. [VerfasserIn]   i
 Over, Tobias [VerfasserIn]   i
 Spillmann, Uwe [VerfasserIn]   i
 Weber, Günter [VerfasserIn]   i
 Zhu, Binghui [VerfasserIn]   i
 Enss, Christian [VerfasserIn]   i
 Stöhlker, Thomas [VerfasserIn]   i
Titel:Integration of maXs-type microcalorimeter detectors for high-resolution x-ray spectroscopy into the experimental environment at the CRYRINGESR electron cooler
Verf.angabe:Ph Pfäfflein, S Allgeier, S Bernitt, A Fleischmann, M Friedrich, Ch Hahn, D Hengstler, M.O Herdrich, A Kalinin, F.M Kröger, P Kuntz, M Lestinsky, B Löher, E.B Menz, T Over, U Spillmann, G Weber, B Zhu, Ch Enss and Th Stöhlker
E-Jahr:2022
Jahr:14 October 2022
Umfang:14 S.
Fussnoten:Gesehen am 06.12.2022
Titel Quelle:Enthalten in: Physica scripta
Ort Quelle:Bristol : IoP Publ., 1970
Jahr Quelle:2022
Band/Heft Quelle:97(2022), 11, Artikel-ID 114005, Seite 1-14
ISSN Quelle:1402-4896
Abstract:We report on the first integration of novel magnetic microcalorimeter detectors (MMCs), developed within SPARC (Stored Particles Atomic Physics Research Collaboration), into the experimental environment of storage rings at GSI 6 , Darmstadt, namely at the electron cooler of CRYRING@ESR. Two of these detector systems were positioned at the 0° and 180° view ports of the cooler section to obtain high-resolution x-ray spectra originating from a stored beam of hydrogen-like uranium interacting with the cooler electrons. While previous test measurements with microcalorimeters at the accelerator facility of GSI were conducted in the mode of well-established stand-alone operation, for the present experiment we implemented several notable modifications to exploit the full potential of this type of detector for precision x-ray spectroscopy of stored heavy ions. Among these are a new readout system compatible with the multi branch system data acquisition platform of GSI, the synchronization of a quasi-continuous energy calibration with the operation cycle of the accelerator facility, as well as the first exploitation of the maXs detectors’ time resolution to apply coincidence conditions for the detection of photons and charge-changed ions.
DOI:doi:10.1088/1402-4896/ac93be
URL:Bitte beachten Sie: Dies ist ein Bibliographieeintrag. Ein Volltextzugriff für Mitglieder der Universität besteht hier nur, falls für die entsprechende Zeitschrift/den entsprechenden Sammelband ein Abonnement besteht oder es sich um einen OpenAccess-Titel handelt.

Volltext ; Verlag: https://doi.org/10.1088/1402-4896/ac93be
 Volltext: https://iopscience.iop.org/article/10.1088/1402-4896/ac93be
 DOI: https://doi.org/10.1088/1402-4896/ac93be
Datenträger:Online-Ressource
Sprache:eng
K10plus-PPN:1824511914
Verknüpfungen:→ Zeitschrift

Permanenter Link auf diesen Titel (bookmarkfähig):  https://katalog.ub.uni-heidelberg.de/titel/68993299   QR-Code
zum Seitenanfang