Navigation überspringen
Universitätsbibliothek Heidelberg
Status: Bibliographieeintrag

Verfügbarkeit
Standort: ---
Exemplare: ---
heiBIB
 Online-Ressource
Verfasst von:Patel, Chirayu [VerfasserIn]   i
 Peterson, Jennifer [VerfasserIn]   i
 Aznar, Marianne [VerfasserIn]   i
 Tseng, Yolanda D. [VerfasserIn]   i
 Lester, Scott [VerfasserIn]   i
 Pafundi, Deanna [VerfasserIn]   i
 Flampouri, Stella [VerfasserIn]   i
 Mohindra, Pranshu [VerfasserIn]   i
 Parikh, Rahul R. [VerfasserIn]   i
 Mailhot Vega, Raymond [VerfasserIn]   i
 König, Laila [VerfasserIn]   i
 Plastaras, John P. [VerfasserIn]   i
 Bates, James E. [VerfasserIn]   i
 Loap, Pierre [VerfasserIn]   i
 Kirova, Youlia M. [VerfasserIn]   i
 Orlandi, Ester [VerfasserIn]   i
 Lütgendorf-Caucig, Carola [VerfasserIn]   i
 Ntentas, Georgios [VerfasserIn]   i
 Hoppe, Bradford [VerfasserIn]   i
Titel:Systematic review for deep inspiration breath hold in proton therapy for mediastinal lymphoma
Titelzusatz:A PTCOG Lymphoma Subcommittee report and recommendations
Verf.angabe:Chirayu G. Patel, Jennifer Peterson, Marianne Aznar, Yolanda D. Tseng, Scott Lester, Deanna Pafundi, Stella Flampouri, Pranshu Mohindra, Rahul R. Parikh, Raymond Mailhot Vega, Laila Konig, John P. Plastaras, James E. Bates, Pierre Loap, Youlia M. Kirova, Ester Orlandi, Carola Lütgendorf-Caucig, Georgios Ntentas, Bradford Hoppe
E-Jahr:2022
Jahr:3 November 2022
Umfang:12 S.
Fussnoten:Online verfügbar 14 Oktober 2022, Artikelversion 3 November 2022 ; Gesehen am 24.01.2023
Titel Quelle:Enthalten in: Radiotherapy and oncology
Ort Quelle:Amsterdam [u.a.] : Elsevier Science, 1983
Jahr Quelle:2022
Band/Heft Quelle:177(2022), Seite 21-32
ISSN Quelle:1879-0887
Abstract:Purpose - To systematically review all dosimetric studies investigating the impact of deep inspiration breath hold (DIBH) compared with free breathing (FB) in mediastinal lymphoma patients treated with proton therapy as compared to IMRT (intensity-modulated radiation therapy)-DIBH. - Materials and Methods - We conducted a systematic review in accordance with the Preferred Reporting Items for Systematic Reviews and Meta-Analyses guideline using the PubMed database to identify studies of mediastinal lymphoma patients with dosimetric comparisons of proton-FB and/or proton-DIBH with IMRT-DIBH. Parameters included mean heart (MHD), lung (MLD), and breast (MBD) doses, among other parameters. Case reports were excluded. Absolute differences in mean doses>1Gy between comparators were considered to be clinically meaningful. - Results - As of April 2021, eight studies fit these criteria (n=8), with the following comparisons: proton-FB vs IMRT-DIBH (n=5), proton-DIBH vs proton-FB (n=5), and proton-DIBH vs IMRT-DIBH (n=8). When comparing proton-FB with IMRT-DIBH in 5 studies, MHD was reduced with proton-FB in 2 studies, was similar (<1 Gy difference) in 2 studies, and increased in 1 study. On the other hand, MLD and MBD were reduced with proton-FB in 3 and 4 studies, respectively. When comparing proton-DIBH with proton-FB, MHD and MLD were reduced with proton DIBH in 4 and 3 studies, respectively, while MBD remained similar. Compared with IMRT-DIBH in 8 studies, proton-DIBH reduced the MHD in 7 studies and was similar in 1 study. Furthermore, MLD and MBD were reduced with proton-DIBH in 8 and 6 studies respectively. Integral dose was similar between proton-FB and proton-DIBH, and both were substantially lower than IMRT-DIBH. - Conclusion - Accounting for heart, lung, breast, and integral dose, proton therapy (FB or DIBH) was superior to IMRT-DIBH. Proton-DIBH can lower dose to the lungs and heart even further compared with proton-FB, depending on disease location in the mediastinum, and organ-sparing and target coverage priorities.
DOI:doi:10.1016/j.radonc.2022.10.003
URL:Bitte beachten Sie: Dies ist ein Bibliographieeintrag. Ein Volltextzugriff für Mitglieder der Universität besteht hier nur, falls für die entsprechende Zeitschrift/den entsprechenden Sammelband ein Abonnement besteht oder es sich um einen OpenAccess-Titel handelt.

Volltext: https://doi.org/10.1016/j.radonc.2022.10.003
 Volltext: https://www.sciencedirect.com/science/article/pii/S0167814022044978