Titel:Pumpless Extracorporeal Hemadsorption Technique (pEHAT)
Titelzusatz:a proof-of-concept animal study
Verf.angabe:Mascha O. Fiedler, Ralf M. Muellenbach, Caroline Rolfes, Christopher Lotz, Felix Nickel, Beat P. Müller-Stich, Alexander Supady, Philipp M. Lepper, Markus A. Weigand, Patrick Meybohm, Armin Kalenka and Christian Reyher
E-Jahr:2022
Jahr:18 November 2022
Umfang:8 S.
Fussnoten:Gesehen am 31.01.2023
Titel Quelle:Enthalten in: Journal of Clinical Medicine
Ort Quelle:Basel : MDPI, 2012
Jahr Quelle:2022
Band/Heft Quelle:11(2022), 22, Artikel-ID 6815, Seite 1-8
ISSN Quelle:2077-0383
Abstract:Background: Extracorporeal hemadsorption eliminates proinflammatory mediators in critically ill patients with hyperinflammation. The use of a pumpless extracorporeal hemadsorption technique allows its early usage prior to organ failure and the need for an additional medical device. In our animal model, we investigated the feasibility of pumpless extracorporeal hemadsorption over a wide range of mean arterial pressures (MAP). Methods: An arteriovenous shunt between the femoral artery and femoral vein was established in eight pigs. The hemadsorption devices were inserted into the shunt circulation; four pigs received CytoSorb® and four Oxiris® hemadsorbers. Extracorporeal blood flow was measured in a range between mean arterial pressures of 45-85 mmHg. Mean arterial pressures were preset using intravenous infusions of noradrenaline, urapidil, or increased sedatives. Results: Extracorporeal blood flows remained well above the minimum flows recommended by the manufacturers throughout all MAP steps for both devices. Linear regression resulted in CytoSorb® blood flow [mL/min] = 4.226 × MAP [mmHg] − 3.496 (R-square 0.8133) and Oxiris® blood flow [mL/min] = 3.267 × MAP [mmHg] + 57.63 (R-square 0.8708), respectively. Conclusion: Arteriovenous pumpless extracorporeal hemadsorption resulted in sufficient blood flows through both the CytoSorb® and Oxiris® devices over a wide range of mean arterial blood pressures and is likely an intriguing therapeutic option in the early phase of septic shock or hyperinflammatory syndromes.
DOI:doi:10.3390/jcm11226815
URL:Bitte beachten Sie: Dies ist ein Bibliographieeintrag. Ein Volltextzugriff für Mitglieder der Universität besteht hier nur, falls für die entsprechende Zeitschrift/den entsprechenden Sammelband ein Abonnement besteht oder es sich um einen OpenAccess-Titel handelt.

Volltext: https://doi.org/10.3390/jcm11226815
 Volltext: https://www.mdpi.com/2077-0383/11/22/6815
 DOI: https://doi.org/10.3390/jcm11226815
Datenträger:Online-Ressource
Sprache:eng
Sach-SW:adsorption
 animal model
 arteriovenous extracorporeal hemadsorption technique
 blood purification
 cytokines
 endotoxin
 extracorporeal hemadsorption
 extracorporeal techniques in hemadsorption therapy
 immunosorbents
 septic shock
K10plus-PPN:1832748464
Verknüpfungen:→ Zeitschrift

Permanenter Link auf diesen Titel (bookmarkfähig):  https://katalog.ub.uni-heidelberg.de/titel/69028403   QR-Code
zum Seitenanfang