Titel:Reliability and accuracy of intraoral radiography, cone beam CT, and dental MRI for evaluation of peri-implant bone lesions at zirconia implants
Titelzusatz:an ex vivo feasibility study
Verf.angabe:Nikolai Miotk, Franz Sebastian Schwindling, Moussa Zidan, Alexander Juerchott, Peter Rammelsberg, Zahra Hosseini, Mathias Nittka, Sabine Heiland, Martin Bendszus, Tim Hilgenfeld
E-Jahr:2023
Jahr:14 January 2023
Umfang:8 S.
Fussnoten:Gesehen am 06.03.2023
Titel Quelle:Enthalten in: Journal of dentistry
Ort Quelle:Amsterdam [u.a.] : Elsevier Science, 1972
Jahr Quelle:2023
Band/Heft Quelle:130(2023), Artikel-ID 104422, Seite 1-8
ISSN Quelle:1879-176X
Abstract:Objectives - To determine the reliability and accuracy of intraoral radiography (IR), cone-beam-computed tomography (CBCT), and dental magnetic resonance imaging (dMRI) in measuring peri‑implant bone defects around single zirconia implants. - Methods - Twenty-four zirconia implants were inserted in bovine ribs with various peri‑implant defect sizes and morphologies. True defect extent was measured without implant in CBCT. Defects were measured twice in IR, CBCT, and dMRI with the inserted implant by three experienced readers. Reliability was assessed by ICC, accuracy by the Friedman test, and post-hoc-Tukey's test. - Results - A comparable good to excellent intra- and inter-reader reliability was observed for all modalities (intra-/inter-rater-CC range for IR; CBCT; dMRI: 0.81-0.91/0.79;0.87-0.97/0.96;0.87-0.95/0.94). Accuracy was generally high, with mean errors below 1 mm in all directions. However, measuring defect depth in the mesiodistal direction was significantly more accurate in dMRI (0.65 ± 0.38 mm) compared to IR (2.71 ± 1.91 mm), and CBCT (1.98 ± 1.97 mm), p-values ≤ 0.0001 respectively ≤ 0.01. - Conclusions - Osseous defects around zirconia implants can be reliably measured in IR/CBCT/dMRI in the mesiodistal directions. In addition, CBCT and dMRI allow assessment of the buccolingual directions. dMRI provides a comparable accuracy in all directions, except for the mesiodistal defect depth, where it outperforms IR and CBCT.
DOI:doi:10.1016/j.jdent.2023.104422
URL:Bitte beachten Sie: Dies ist ein Bibliographieeintrag. Ein Volltextzugriff für Mitglieder der Universität besteht hier nur, falls für die entsprechende Zeitschrift/den entsprechenden Sammelband ein Abonnement besteht oder es sich um einen OpenAccess-Titel handelt.

Volltext: https://doi.org/10.1016/j.jdent.2023.104422
 Volltext: https://www.sciencedirect.com/science/article/pii/S0300571223000143
 DOI: https://doi.org/10.1016/j.jdent.2023.104422