Titel:Low dose multi-detector CT of the chest (iLEAD Study)
Titelzusatz:visual ranking of different simulated mAs levels
Verf.angabe:Julia Ley-Zaporozhan, Sebastian Ley, Frank Krummenauer, Yoshiharu Ohno, Hiroto Hatabu, Hans-Ulrich Kauczor
E-Jahr:2010
Jahr:February 2010
Umfang:6 S.
Fussnoten:Online verfügbar 2. Dezember 2008 ; Gesehen am 14.03.2023
Titel Quelle:Enthalten in: European journal of radiology
Ort Quelle:Amsterdam [u.a.] : Elsevier Science, 1990
Jahr Quelle:2010
Band/Heft Quelle:73(2010), 2, Seite 428-433
ISSN Quelle:1872-7727
Abstract:Purpose - Detailed evaluation of the lung parenchyma might be impaired by use of low dose CT as image noise increases and subsequently image quality decreases. The aim of our study was to determine the accuracy of visual perception of differences in image quality and noise at low dose chest CT. - Materials and methods - Forty-four patients suffering from emphysema underwent CT (Aquilion-16, 120kV, 150mAs, 1mm-collimation). Original raw data were used for simulation of 10 different mAs settings from 10mAs to 100mAs in 10mAs increments. Three representative hard copy images (carina, 4cm above, 5cm below) were printed for evaluation of lung parenchyma (high-resolution kernel, lung window) and mediastinum (soft-kernel, soft tissue window). Ranking of expected low mAs level was performed for lung and soft tissue separately based on visual perception by three-blinded chest radiologist independently. Results were compared to the real simulated mAs. - Results - The accuracy for correct ranking of the original 150mAs scan was 89% for lung and 86% for soft tissue while it was 99% for the simulated 10mAs for both windows. In comparison to the lowest mAs a significant error increase was found for the lung at 60-100mAs (with error increase of 30-47%) for reader-I; 60-100mAs for (33-64%) for reader-II and 70-100mAs (38-57%) for reader-III. For the soft tissue: 60-150mAs (with error increase of 28-63%) for reader-I; 50-100mAs (35-56%) for reader-II and 50-90mAs (35-40%) for reader-III. - Conclusion - Simulated dose levels below 60mAs (=42mAseff) were clearly differentiated from higher dose levels by all readers. Therefore, imaging doses could be lowered down to 60mAs without a diagnostically relevant increase in noise impairing image quality.
DOI:doi:10.1016/j.ejrad.2008.10.006
URL:Bitte beachten Sie: Dies ist ein Bibliographieeintrag. Ein Volltextzugriff für Mitglieder der Universität besteht hier nur, falls für die entsprechende Zeitschrift/den entsprechenden Sammelband ein Abonnement besteht oder es sich um einen OpenAccess-Titel handelt.

Volltext: https://doi.org/10.1016/j.ejrad.2008.10.006
 Volltext: https://www.sciencedirect.com/science/article/pii/S0720048X08005627
 DOI: https://doi.org/10.1016/j.ejrad.2008.10.006
Datenträger:Online-Ressource
Sprache:eng
Sach-SW:CT
 Emphysema
 Low dose
 Lung
 Radiation dose
K10plus-PPN:1839095857
Verknüpfungen:→ Zeitschrift

Permanenter Link auf diesen Titel (bookmarkfähig):  https://katalog.ub.uni-heidelberg.de/titel/69051506   QR-Code
zum Seitenanfang