Titel:Selectivity issues in targeted metabolomics
Titelzusatz:separation of phosphorylated carbohydrate isomers by mixed-mode hydrophilic interaction/weak anion exchange chromatography
Verf.angabe:Helmut Hinterwirth, Michael Lämmerhofer, Beatrix Preinerstorfer, Andrea Gargano, Roland Reischl, Wolfgang Bicker, Oliver Trapp, Lothar Brecker, Wolfgang Lindner
E-Jahr:2010
Jahr:[November 2010]
Umfang:10 S.
Fussnoten:First published: 07 October 2010 ; Gesehen am 15.05.2023
Titel Quelle:Enthalten in: Journal of separation science
Ort Quelle:Weinheim : Wiley-VCH, 2000
Jahr Quelle:2010
Band/Heft Quelle:33(2010), 21, Seite 3273-3282
ISSN Quelle:1615-9314
Abstract:Phosphorylated carbohydrates are important intracellular metabolites and thus of prime interest in metabolomics research. Complications in their analysis arise from the existence of structural isomers that do have similar fragmentation patterns in MS/MS and are hard to resolve chromatographically. Herein, we present selective methods for the liquid chromatographic separation of sugar phosphates, such as hexose and pentose phosphates, 2- and 3-phosphoglycerate, dihydroxyacetone phosphate and glyceraldehyde 3-phosphate, as well as glucosamine 1- and 6-phosphate utilizing mixed-mode chromatography with reversed-phase/weak anion-exchangers and a charged aerosol detector. The best results were obtained when the reversed-phase/weak anion-exchanger column was operated under hydrophilic interaction liquid chromatography elution conditions. The effects of various chromatographic parameters were examined and are discussed on the basis of a simple stoichiometric displacement model for explaining ion-exchange processes. Employed acidic conditions have led to the complete separation of α- and β-anomers of glucose 6-phosphate at low temperature. The anomers coeluted in a single peak at elevated temperatures (>40°C) (peak coalescence), while at intermediate temperatures on-column interconversion with a plateau in-between resolved anomer peaks was observed with apparent reaction rate constants between 0.1 and 27.8×10−4 s−1. Dynamic HPLC under specified conditions enabled to investigate mutarotation of phosphorylated carbohydrates, their interconversion kinetics, and energy barriers for interconversion. A complex mixture of six hexose phosphate structural isomers could be resolved almost completely.
DOI:doi:10.1002/jssc.201000412
URL:Bitte beachten Sie: Dies ist ein Bibliographieeintrag. Ein Volltextzugriff für Mitglieder der Universität besteht hier nur, falls für die entsprechende Zeitschrift/den entsprechenden Sammelband ein Abonnement besteht oder es sich um einen OpenAccess-Titel handelt.

Volltext: https://doi.org/10.1002/jssc.201000412
 Volltext: https://onlinelibrary.wiley.com/doi/abs/10.1002/jssc.201000412
 DOI: https://doi.org/10.1002/jssc.201000412
Datenträger:Online-Ressource
Sprache:eng
Sach-SW:Charged aerosol detection
 Hydrophilic interaction liquid chromatography (HILIC)
 Mixed-mode stationary phase
 Reversed-phase/weak anion-exchange material
 Sugar phosphate isomers