Titel: | Analysis of bisphenol-propane in dialyzer and its effect on human body |
Verf.angabe: | Chen Yun, Xiaofan He, Ting Xie, Ao-Ieong Chi-Wa, Weilong Li, Zhuoheng Song, Mengyun Xiao, Yu Meng, Bo Hu, Baozhang Guan, Lifeng Yang, Mingjun Ye, Huiyi Zeng, Stanislao Morgera, Bernhard Krämer, Wolfganng, Lianghong Yin, Shaodong Luan, Suhua Xu, and Berthold Hocher |
E-Jahr: | 2023 |
Jahr: | 1. Januar 2023 |
Umfang: | 12 S. |
Fussnoten: | Gesehen am 22.05.2023 |
Titel Quelle: | Enthalten in: Materials express |
Ort Quelle: | Valencia, California : American Scientific Publishers, 2011 |
Jahr Quelle: | 2023 |
Band/Heft Quelle: | 13(2023), 1 vom: Jan., Seite 170-181 |
ISSN Quelle: | 2158-5857 |
Abstract: | The effect of trace solvent bisphenol A (BPA) in polyether sulfone hollow fiber membrane Enttex™-16LF (E60) (produced by 3 M) low-throughput dialyzer was tested in this study. Animal experiments were conducted to evaluate its genotoxicity, carcinogenicity, and teratogenicity upon - chronic exposure. The dialyzer was operated at 200 mL/min and 400 mL/min and coupled with LC-20AT liquid chromatography to detect BPA, which showed that the BPA content was less than 5 μg/kg/d at both flow rates. In animal experiments, the tolerable intake (T.I.) was calculated to - be 0.5 μg/kg/d. With hemodialysis three times per week, the average patient weight was calculated at 70 kg, and the average daily BPA exposure was 0.0306 μg/kg/d. The risk of residual BPA was within the acceptable limit with polyether sulfone membrane Enttex™-16LF - (E60) hollow fiber dialyzer from 3 M, without inducing risk for disability, teratogenicity, or genotoxicity. |
DOI: | doi:10.1166/mex.2023.2327 |
URL: | Bitte beachten Sie: Dies ist ein Bibliographieeintrag. Ein Volltextzugriff für Mitglieder der Universität besteht hier nur, falls für die entsprechende Zeitschrift/den entsprechenden Sammelband ein Abonnement besteht oder es sich um einen OpenAccess-Titel handelt.
Volltext: https://dx.doi.org/10.1166/mex.2023.2327 |
| DOI: https://doi.org/10.1166/mex.2023.2327 |
Datenträger: | Online-Ressource |
Sprache: | eng |
Sach-SW: | Bisphenol A |
| Dialyzer |
| Extractables |
| Hemodialysis |
| Risk Assessment |