Titel:Comparison of four endoluminal radiofrequency ablation devices and four power generators in an ex vivo bovine liver model
Verf.angabe:Stephan Rheinheimer, Anna Jacobsen, Philipp Mayer, Hans-Ulrich Kauczor and Andreas Horst Mahnken
E-Jahr:2021
Jahr:November/December 2021
Umfang:7 S.
Fussnoten:Gesehen am 23.05.2023
Titel Quelle:Enthalten in: World Academy of Sciences journal
Ort Quelle:London : Spandidos Publications, 2019
Jahr Quelle:2021
Band/Heft Quelle:3(2021), 6 vom: Nov./Dez., Seite 1-7
ISSN Quelle:2632-2919
Abstract:The aim of the present study was to investigate the <em>ex vivo</em> results of four different endoluminal bipolar radiofrequency ablation (RFA) probes at different energy settings and using four different power generators. <em>Ex vivo</em> RFA was performed on bovine liver using four different bipolar RFA probes: i) Habib™ EndoHPB (EMcision); ii) Habib™ VesOpen (EMcision); iii) Celon ProCurve micro 300‑C09 (Olympus Corporation); and iv) Celon ProCurve 1200 S15 (Olympus Corporation). The following generators were also used: Erbe Vio 300D, KLS Martin Maxium, Olympus CelonPOWER and Boston RF3000. Overall, 430 ablations were carried out. The results revealed significant differences in the size of the achieved lesions and the duration of ablation (P<0.05) between the four different ablation devices. The maximum lesion diameters achieved with the devises were as follows: HabibTM EndoHPB, 13 watts (W; mean ± standard deviation, 10.3±1.8 mm); Habib™ VesOpen, 12 W (11.3±0.6); Celon ProCurve micro, 2 W (7.9±2.2); and Celon ProCurve 1200, 10 W (9.2±1.1). The maximum lesion diameters induced by the various generators differed significantly. On the whole, the present study demonstrates that lesion size and ideal power settings vary between different endoluminal ablation devices and generators. The combination of the probe and generator should not be varied in clinical practice to ensure reliable results.
DOI:doi:10.3892/wasj.2021.128
URL:Bitte beachten Sie: Dies ist ein Bibliographieeintrag. Ein Volltextzugriff für Mitglieder der Universität besteht hier nur, falls für die entsprechende Zeitschrift/den entsprechenden Sammelband ein Abonnement besteht oder es sich um einen OpenAccess-Titel handelt.

kostenfrei: Volltext: https://doi.org/10.3892/wasj.2021.128
 kostenfrei: Volltext: https://www.spandidos-publications.com/10.3892/wasj.2021.128
 DOI: https://doi.org/10.3892/wasj.2021.128
Datenträger:Online-Ressource
Sprache:eng
K10plus-PPN:1845982703
Verknüpfungen:→ Zeitschrift

Permanenter Link auf diesen Titel (bookmarkfähig):  https://katalog.ub.uni-heidelberg.de/titel/69078294   QR-Code
zum Seitenanfang