Navigation überspringen
Universitätsbibliothek Heidelberg
Status: Bibliographieeintrag

Verfügbarkeit
Standort: ---
Exemplare: ---
heiBIB
 Online-Ressource
Verfasst von:Bauer, Cornelius Jonathan [VerfasserIn]   i
 Teske, Hendrik [VerfasserIn]   i
 Walter, Alexandra [VerfasserIn]   i
 Hoegen, Philipp [VerfasserIn]   i
 Adeberg, Sebastian [VerfasserIn]   i
 Debus, Jürgen [VerfasserIn]   i
 Jäkel, Oliver [VerfasserIn]   i
 Giske, Kristina [VerfasserIn]   i
Titel:Biofidelic image registration for head and neck region utilizing an in-silico articulated skeleton as a transformation model
Verf.angabe:Cornelius J. Bauer, Hendrik Teske, Alexandra Walter, Philipp Hoegen, Sebastian Adeberg, Jürgen Debus, Oliver Jäkel and Kristina Giske
E-Jahr:2023
Jahr:19 April 2023
Umfang:12 S.
Fussnoten:Gesehen am 14.06.2023
Titel Quelle:Enthalten in: Physics in medicine and biology
Ort Quelle:Bristol : IOP Publ., 1956
Jahr Quelle:2023
Band/Heft Quelle:68(2023), 9 vom: Apr., Artikel-ID 095006, Seite 1-12
ISSN Quelle:1361-6560
Abstract:Objective. We propose an integration scheme for a biomechanical motion model into a deformable image registration. We demonstrate its accuracy and reproducibility for adaptive radiation therapy in the head and neck region. Approach. The novel registration scheme for the bony structures in the head and neck regions is based on a previously developed articulated kinematic skeleton model. The realized iterative single-bone optimization process directly triggers posture changes of the articulated skeleton, exchanging the transformation model within the deformable image registration process. Accuracy in terms of target registration errors in the bones is evaluated for 18 vector fields of three patients between each planning CT and six fraction CT scans distributed along the treatment course. Main results. The median of target registration error distribution of the landmark pairs is 1.4 ± 0.3 mm. This is sufficient accuracy for adaptive radiation therapy. The registration performs equally well for all three patients and no degradation of the registration accuracy can be observed throughout the treatment. Significance. Deformable image registration, despite its known residual uncertainties, is until now the tool of choice towards online re-planning automation. By introducing a biofidelic motion model into the optimization, we provide a viable way towards an in-build quality assurance.
DOI:doi:10.1088/1361-6560/acc7f1
URL:Bitte beachten Sie: Dies ist ein Bibliographieeintrag. Ein Volltextzugriff für Mitglieder der Universität besteht hier nur, falls für die entsprechende Zeitschrift/den entsprechenden Sammelband ein Abonnement besteht oder es sich um einen OpenAccess-Titel handelt.

kostenfrei: Volltext: https://doi.org/10.1088/1361-6560/acc7f1
 kostenfrei: Volltext: https://dx.doi.org/10.1088/1361-6560/acc7f1
 DOI: https://doi.org/10.1088/1361-6560/acc7f1
Datenträger:Online-Ressource
Sprache:eng
K10plus-PPN:1848961634
Verknüpfungen:→ Zeitschrift

Permanenter Link auf diesen Titel (bookmarkfähig):  https://katalog.ub.uni-heidelberg.de/titel/69085611   QR-Code
zum Seitenanfang