| Online-Ressource |
Verfasst von: | Müller, Julian [VerfasserIn]  |
| Nentwich, Karin [VerfasserIn]  |
| Ene, Elena [VerfasserIn]  |
| Berkovitz, Artur [VerfasserIn]  |
| Sonne, Kai [VerfasserIn]  |
| Chakarov, Ivaylo [VerfasserIn]  |
| Barth, Sebastian [VerfasserIn]  |
| Waechter, Christian [VerfasserIn]  |
| Behnes, Michael [VerfasserIn]  |
| Akın, Ibrahim [VerfasserIn]  |
| Halbfaß, Philipp [VerfasserIn]  |
| Deneke, Thomas [VerfasserIn]  |
Titel: | Radiofrequency ablation of atrial fibrillation - 50 W or 90 W? |
Titelzusatz: | original articles |
Verf.angabe: | Julian Mueller, Karin Nentwich, Elena Ene, Artur Berkovitz, Kai Sonne, Ivaylo Chakarov, Sebastian Barth, Christian Waechter, Michael Behnes, Ibrahim Akin, Philipp Halbfass, Thomas Deneke |
E-Jahr: | 2022 |
Jahr: | 19 September 2022 |
Umfang: | 10 S. |
Fussnoten: | Gesehen am 20.06.2023 |
Titel Quelle: | Enthalten in: Journal of cardiovascular electrophysiology |
Ort Quelle: | Oxford : Wiley-Blackwell, 1990 |
Jahr Quelle: | 2022 |
Band/Heft Quelle: | 33(2022), 12, Seite 2504-2513 |
ISSN Quelle: | 1540-8167 |
Abstract: | Background: This study sought to evaluate the short and midterm efficacy and safety of the novel very high power very short duration (vHPvSD) 90 W approach compared to HPSD 50 W for atrial fibrillation (AF) ablation as well as reconnection patterns of 90 W ablations. Methods and Results: Consecutive patients undergoing first AF ablation with vHPvSD (90 W; predefined ablation time of 3 s for posterior wall ablation and 4 s for anterior wall ablation) were compared to patients using HPSD (50 W; ablation index-guided; AI 350 for posterior wall ablation, AI 450 for anterior wall ablation) retrospectively. A total of 84 patients (67.1 ± 9.8 years; 58% male; 47% paroxysmal AF) were included (42 with 90 W, 42 with 50 W) out of a propensity score-matched cohort. 90 W ablations revealed shorter ablation times (10.5 ± 6.7 min vs. 17.4 ± 9.9 min; p = .001). No major complication occurred. 90 W ablations revealed lower first pass PVI rates (40% vs. 62%; p = .049) and higher AF recurrences during blanking period (38% vs. 12%; p = .007). After 12 months, both ablation approaches revealed comparable midterm outcomes (62% vs. 70%; log-rank p = .452). In a multivariable Cox regression model, persistent AF (hazard ratio [HR]: 1.442, 95% confidence interval [CI]: 1.035-2.010, p = .031) and increased procedural duration (HR: 1.011, 95% CI: 1.005-1.017, p = .001) were identified as independent predictors of AF recurrence during follow-up. Conclusions: AF ablation using 90 W vHPvSD reveals a similar safety profile compared to 50 W ablation with shorter ablation times. However, vHPvSD ablation was associated with lower rates of first-pass isolations and increased AF recurrences during the blanking period. After 12 months, 90 W revealed comparable efficacy results to 50 W ablations in a nonrandomized, propensity-matched comparison. |
DOI: | doi:10.1111/jce.15681 |
URL: | Bitte beachten Sie: Dies ist ein Bibliographieeintrag. Ein Volltextzugriff für Mitglieder der Universität besteht hier nur, falls für die entsprechende Zeitschrift/den entsprechenden Sammelband ein Abonnement besteht oder es sich um einen OpenAccess-Titel handelt.
Volltext: https://doi.org/10.1111/jce.15681 |
| Volltext: http://onlinelibrary.wiley.com/doi/abs/10.1111/jce.15681 |
| DOI: https://doi.org/10.1111/jce.15681 |
Datenträger: | Online-Ressource |
Sprache: | eng |
Sach-SW: | atrial fibrillation |
| endoscopically detected esophageal lesion |
| prognosis |
| pulmonary vein isolation |
| very high-power short duration ablation |
K10plus-PPN: | 183784125X |
Verknüpfungen: | → Zeitschrift |
Radiofrequency ablation of atrial fibrillation - 50 W or 90 W? / Müller, Julian [VerfasserIn]; 19 September 2022 (Online-Ressource)