| Online-Ressource |
Verfasst von: | Preisner, Fabian [VerfasserIn]  |
| Hayes, Jennifer [VerfasserIn]  |
| Charlet, Tobias [VerfasserIn]  |
| Carinci, Flavio [VerfasserIn]  |
| Hielscher, Thomas [VerfasserIn]  |
| Schwarz, Daniel [VerfasserIn]  |
| Vollherbst, Dominik [VerfasserIn]  |
| Breckwoldt, Michael O. [VerfasserIn]  |
| Jesser, Jessica [VerfasserIn]  |
| Heiland, Sabine [VerfasserIn]  |
| Bendszus, Martin [VerfasserIn]  |
| Hilgenfeld, Tim [VerfasserIn]  |
Titel: | Simultaneous multislice accelerated TSE for improved spatiotemporal resolution and diagnostic accuracy in magnetic resonance neurography |
Titelzusatz: | a feasibility study |
Verf.angabe: | Fabian Preisner, Jennifer C. Hayes, Tobias Charlet, Flavio Carinci, Thomas Hielscher, Daniel Schwarz, Dominik F. Vollherbst, Michael O. Breckwoldt, Jessica Jesser, Sabine Heiland, Martin Bendszus, Tim Hilgenfeld |
E-Jahr: | 2023 |
Jahr: | May 2023 |
Umfang: | 9 S. |
Fussnoten: | Gesehen am 20.06.2023 |
Titel Quelle: | Enthalten in: Investigative radiology |
Ort Quelle: | Philadelphia, Pa. : Lippincott Williams & Wilkins, 1966 |
Jahr Quelle: | 2023 |
Band/Heft Quelle: | 58(2023), 5 vom: Mai, Seite 363-371 |
ISSN Quelle: | 1536-0210 |
Abstract: | Objectives - This study aims to evaluate the utility of simultaneous multislice (SMS) acceleration for routine magnetic resonance neurography (MRN) at 3 T. - Materials and Methods - Patients with multiple sclerosis underwent MRN of the sciatic nerve consisting of a standard fat-saturated T2-weighted turbo spin echo (TSE) sequence using integrated parallel acquisition technique (PAT2) acceleration and 2 T2 TSE sequences using a combination of PAT-SMS acceleration (1) to reduce scan time (PAT2-SMS2; SMS-TSEFAST) and (2) for time neutral increase of in-plane resolution (PAT1-SMS2; SMS-TSEHR). Acquisition times were 5:29 minutes for the standard T2 TSE, 3:12 minutes for the SMS-TSEFAST, and 5:24 minutes for the SMS-TSEHR. Six qualitative imaging parameters were analyzed by 2 blinded readers using a 5-point Likert scale and T2 nerve lesions were quantified, respectively. Qualitative and quantitative image parameters were compared, and both interrater and intrarater reproducibility were statistically assessed. In addition, signal-to-noise ratio/contrast-to-noise ratio (CNR) was obtained in healthy controls using the exact same imaging protocol. - Results - A total of 15 patients with MS (mean age ± standard deviation, 38.1 ± 11 years) and 10 healthy controls (mean age, 29.1 ± 7 years) were enrolled in this study. CNR analysis was highly reliable (intraclass correlation coefficient, 0.755-0.948) and revealed a significant CNR decrease for the sciatic nerve for both SMS protocols compared with standard T2 TSE (SMS-TSEFAST/SMS-TSEHR, −39%/−55%; P ≤ 0.01). Intrarater and interrater reliability of qualitative image review was good to excellent (κ: 0.672-0.971/0.617-0.883). Compared with the standard T2 TSE sequence, both SMS methods were shown to be superior in reducing pulsatile flow artifacts (P < 0.01). Ratings for muscle border sharpness, detailed muscle structures, nerve border sharpness, and nerve fascicular structure did not differ significantly between the standard T2 TSE and the SMS-TSEFAST (P > 0.05) and were significantly better for the SMS-TSEHR than for standard T2 TSE (P < 0.001). Muscle signal homogeneity was mildly inferior for both SMS-TSEFAST (P > 0.05) and SMS-TSEHR (P < 0.001). A significantly higher number of T2 nerve lesions were detected by SMS-TSEHR (P ≤ 0.01) compared with the standard T2 TSE and SMS-TSEFAST, whereas no significant difference was observed between the standard T2 TSE and SMS-TSEFAST. - Conclusions - Implementation of SMS offers either to substantially reduce acquisition time by over 40% without significantly impeding image quality compared with the standard T2 TSE or to increase in-plane resolution for a high-resolution approach and improved depiction of T2 nerve lesions while keeping acquisition times constant. This addresses the specific needs of MRN by providing different imaging approaches for 2D clinical MRN. |
DOI: | doi:10.1097/RLI.0000000000000940 |
URL: | Bitte beachten Sie: Dies ist ein Bibliographieeintrag. Ein Volltextzugriff für Mitglieder der Universität besteht hier nur, falls für die entsprechende Zeitschrift/den entsprechenden Sammelband ein Abonnement besteht oder es sich um einen OpenAccess-Titel handelt.
Volltext: https://doi.org/10.1097/RLI.0000000000000940 |
| Volltext: https://journals.lww.com/investigativeradiology/Abstract/2023/05000/Simultaneous_Multislice_Accelerated_TSE_for.8.aspx |
| DOI: https://doi.org/10.1097/RLI.0000000000000940 |
Datenträger: | Online-Ressource |
Sprache: | eng |
K10plus-PPN: | 1850601844 |
Verknüpfungen: | → Zeitschrift |
Simultaneous multislice accelerated TSE for improved spatiotemporal resolution and diagnostic accuracy in magnetic resonance neurography / Preisner, Fabian [VerfasserIn]; May 2023 (Online-Ressource)