Status: Bibliographieeintrag
Standort: ---
Exemplare:
---
| Online-Ressource |
Verfasst von: | Rues, Stefan [VerfasserIn]  |
| Kröger, Elke [VerfasserIn]  |
| Müller, Denise [VerfasserIn]  |
| Schmitter, Marc [VerfasserIn]  |
Titel: | Effect of firing protocols on cohesive failure of all-ceramic crowns |
Verf.angabe: | Stefan Rues, Elke Kröger, Denise Müller, Marc Schmitter |
E-Jahr: | 2010 |
Jahr: | 27 August 2010 |
Umfang: | 8 S. |
Fussnoten: | Gesehen am 22.06.2023 |
Titel Quelle: | Enthalten in: Journal of dentistry |
Ort Quelle: | Amsterdam [u.a.] : Elsevier Science, 1972 |
Jahr Quelle: | 2010 |
Band/Heft Quelle: | 38(2010), 12 vom: Dez., Seite 987-994 |
ISSN Quelle: | 1879-176X |
Abstract: | Objectives - The mechanical properties of veneering material in all-ceramic restorations are inferior to those of high-strength ceramics. The objective of this study was to assess the effect of three different firing protocols (different cooling times) on cohesive failure of veneered all-ceramic crowns using a newly developed in vitro test design. - Methods - A prepared anterior maxillary incisor was used to produce geometrically identical crowns (n=68) with a zirconia framework 0.4mm thick veneered with two different ceramics and prepared by use of three different firing protocols. Twenty crowns were loaded until fracture without artificial ageing; the other crowns underwent thermocycling and chewing simulation before ultimate-load testing. Statistical analysis was performed using non-parametric tests. - Results - The results showed that a reduced temperature decrease after firing led to better performance of all-ceramic anterior crowns in the in vitro tests. A significant difference with regard to firing protocol (p=0.006) was observed for one veneering ceramic material only, however. - Conclusion - It can therefore be concluded that the test design presented enabled sensitive measurement of the effect of firing protocol on cohesive failure of all-ceramic crowns. The modified firing protocol with 6min additional cooling time resulted in greater resistance. |
DOI: | doi:10.1016/j.jdent.2010.08.014 |
URL: | Bitte beachten Sie: Dies ist ein Bibliographieeintrag. Ein Volltextzugriff für Mitglieder der Universität besteht hier nur, falls für die entsprechende Zeitschrift/den entsprechenden Sammelband ein Abonnement besteht oder es sich um einen OpenAccess-Titel handelt.
Volltext: https://doi.org/10.1016/j.jdent.2010.08.014 |
| Volltext: https://www.sciencedirect.com/science/article/pii/S0300571210002162 |
| DOI: https://doi.org/10.1016/j.jdent.2010.08.014 |
Datenträger: | Online-Ressource |
Sprache: | eng |
Sach-SW: | Ageing |
| All-ceramic crowns |
| Cohesive failure |
| Firing protocol |
| In vitro test |
K10plus-PPN: | 1850852847 |
Verknüpfungen: | → Zeitschrift |
Effect of firing protocols on cohesive failure of all-ceramic crowns / Rues, Stefan [VerfasserIn]; 27 August 2010 (Online-Ressource)
69088656