Navigation überspringen
Universitätsbibliothek Heidelberg
Status: Bibliographieeintrag

Verfügbarkeit
Standort: ---
Exemplare: ---
heiBIB
 Online-Ressource
Verfasst von:Son, Hyeck Soo [VerfasserIn]   i
 Moon, Loren [VerfasserIn]   i
 Wang, Jiangxia [VerfasserIn]   i
 Eberhart, Charles G. [VerfasserIn]   i
 Jun, Albert S. [VerfasserIn]   i
 Srikumaran, Divya [VerfasserIn]   i
 Soiberman, Uri S. [VerfasserIn]   i
Titel:Histological comparative analysis of Bowman layer grafts procured using 3 different techniques
Verf.angabe:Hyeck-Soo Son, Loren Moon, Jiangxia Wang, Charles G. Eberhart, Albert S. Jun, Divya Srikumaran, Uri S. Soiberman
E-Jahr:2023
Jahr:July 2023
Umfang:6 S.
Fussnoten:Gesehen am 24.07.2023
Titel Quelle:Enthalten in: Cornea
Ort Quelle:Philadelphia, Pa. : Lippincott, Williams & Wilkins, 1982
Jahr Quelle:2023
Band/Heft Quelle:42(2023), 7 vom: Juli, Seite 888-893
ISSN Quelle:1536-4798
Abstract:Purpose: - The objective of this study is to perform a histological analysis of Bowman layer (BL) grafts. - Methods: - BL grafts were procured from 13 human cadaver corneal tissues using 3 different donor preparation techniques. Subsequently, the grafts were fixed in 10% buffered formalin phosphate and embedded in paraffin. Hematoxylin and eosin sections of BL grafts were obtained and analyzed under a light microscope. BL and full graft thickness were measured using an image-processing software. - Results: - All 13 BL grafts contained residual anterior stromal tissue. BL stripping using Kelman-McPherson and Moorfield forceps (technique 3) achieved the thinnest graft thickness with a mean full graft thickness of 18.7 μm (95% confidence interval [CI], −9.8 to 47.2) at the thinnest point of the graft, whereas BL procurement using the Melles lamellar dissector (technique 2) led to the highest mean full graft thickness of 279.9 μm (95% CI, 251.4-308.5) even at the thinnest area of the graft. By contrast, BL dissection using a blunt dissector (technique 1) provided a mean full graft thickness of 70.2 μm (95% CI, 40.4-100.1) at the graft's thinnest point. Although peripheral graft tears occurred in 50%, 50%, and 100% of techniques 1, 2, and 3, respectively, intact 6.25-mm diameter BL grafts could be secured in 50%, 100%, and 80% of techniques 1, 2, and 3, respectively. - Conclusions: - None of the techniques used led to the procurement of pure BL grafts devoid of the anterior stroma. Peripheral scoring with a thin needle and tissue manipulation with Kelman-McPherson and Moorfield forceps led to the thinnest grafts in this study.
DOI:doi:10.1097/ICO.0000000000003260
URL:Bitte beachten Sie: Dies ist ein Bibliographieeintrag. Ein Volltextzugriff für Mitglieder der Universität besteht hier nur, falls für die entsprechende Zeitschrift/den entsprechenden Sammelband ein Abonnement besteht oder es sich um einen OpenAccess-Titel handelt.

Volltext: https://doi.org/10.1097/ICO.0000000000003260
 Volltext: https://journals.lww.com/corneajrnl/Abstract/2023/07000/Histological_Comparative_Analysis_of_Bowman_Layer.11.aspx
 DOI: https://doi.org/10.1097/ICO.0000000000003260
Datenträger:Online-Ressource
Sprache:eng
K10plus-PPN:1853474398
Verknüpfungen:→ Zeitschrift

Permanenter Link auf diesen Titel (bookmarkfähig):  https://katalog.ub.uni-heidelberg.de/titel/69100504   QR-Code
zum Seitenanfang