| Online-Ressource |
Verfasst von: | Son, Hyeck Soo [VerfasserIn]  |
| Moon, Loren [VerfasserIn]  |
| Wang, Jiangxia [VerfasserIn]  |
| Eberhart, Charles G. [VerfasserIn]  |
| Jun, Albert S. [VerfasserIn]  |
| Srikumaran, Divya [VerfasserIn]  |
| Soiberman, Uri S. [VerfasserIn]  |
Titel: | Histological comparative analysis of Bowman layer grafts procured using 3 different techniques |
Verf.angabe: | Hyeck-Soo Son, Loren Moon, Jiangxia Wang, Charles G. Eberhart, Albert S. Jun, Divya Srikumaran, Uri S. Soiberman |
E-Jahr: | 2023 |
Jahr: | July 2023 |
Umfang: | 6 S. |
Fussnoten: | Gesehen am 24.07.2023 |
Titel Quelle: | Enthalten in: Cornea |
Ort Quelle: | Philadelphia, Pa. : Lippincott, Williams & Wilkins, 1982 |
Jahr Quelle: | 2023 |
Band/Heft Quelle: | 42(2023), 7 vom: Juli, Seite 888-893 |
ISSN Quelle: | 1536-4798 |
Abstract: | Purpose: - The objective of this study is to perform a histological analysis of Bowman layer (BL) grafts. - Methods: - BL grafts were procured from 13 human cadaver corneal tissues using 3 different donor preparation techniques. Subsequently, the grafts were fixed in 10% buffered formalin phosphate and embedded in paraffin. Hematoxylin and eosin sections of BL grafts were obtained and analyzed under a light microscope. BL and full graft thickness were measured using an image-processing software. - Results: - All 13 BL grafts contained residual anterior stromal tissue. BL stripping using Kelman-McPherson and Moorfield forceps (technique 3) achieved the thinnest graft thickness with a mean full graft thickness of 18.7 μm (95% confidence interval [CI], −9.8 to 47.2) at the thinnest point of the graft, whereas BL procurement using the Melles lamellar dissector (technique 2) led to the highest mean full graft thickness of 279.9 μm (95% CI, 251.4-308.5) even at the thinnest area of the graft. By contrast, BL dissection using a blunt dissector (technique 1) provided a mean full graft thickness of 70.2 μm (95% CI, 40.4-100.1) at the graft's thinnest point. Although peripheral graft tears occurred in 50%, 50%, and 100% of techniques 1, 2, and 3, respectively, intact 6.25-mm diameter BL grafts could be secured in 50%, 100%, and 80% of techniques 1, 2, and 3, respectively. - Conclusions: - None of the techniques used led to the procurement of pure BL grafts devoid of the anterior stroma. Peripheral scoring with a thin needle and tissue manipulation with Kelman-McPherson and Moorfield forceps led to the thinnest grafts in this study. |
DOI: | doi:10.1097/ICO.0000000000003260 |
URL: | Bitte beachten Sie: Dies ist ein Bibliographieeintrag. Ein Volltextzugriff für Mitglieder der Universität besteht hier nur, falls für die entsprechende Zeitschrift/den entsprechenden Sammelband ein Abonnement besteht oder es sich um einen OpenAccess-Titel handelt.
Volltext: https://doi.org/10.1097/ICO.0000000000003260 |
| Volltext: https://journals.lww.com/corneajrnl/Abstract/2023/07000/Histological_Comparative_Analysis_of_Bowman_Layer.11.aspx |
| DOI: https://doi.org/10.1097/ICO.0000000000003260 |
Datenträger: | Online-Ressource |
Sprache: | eng |
K10plus-PPN: | 1853474398 |
Verknüpfungen: | → Zeitschrift |
Histological comparative analysis of Bowman layer grafts procured using 3 different techniques / Son, Hyeck Soo [VerfasserIn]; July 2023 (Online-Ressource)