Titel:Femoral derotation osteotomy
Titelzusatz:does intraoperative electromagnetic tracking reflect the dynamic outcome?
Verf.angabe:Andreas Geisbüsch, Marco Götze, Cornelia Putz, Hartmut Dickhaus, Thomas Dreher
Jahr:2022
Umfang:9 S.
Fussnoten:First published: 25 August 2021 ; Gesehen am 11.08.2023
Titel Quelle:Enthalten in: Journal of orthopaedic research
Ort Quelle:Hoboken, NJ [u.a.] : Wiley, 1983
Jahr Quelle:2022
Band/Heft Quelle:40(2022), 6, Seite 1312-1320
ISSN Quelle:1554-527X
Abstract:Femoral derotation osteotomy (FDO) is a well-established procedure for the correction of internal rotation gait in children with cerebral palsy. Various studies have demonstrated good results for FDO both in short-term and long-term evaluation with some describing recurrence and over- or under-corrections. The present study evaluates the use of an objective intraoperative derotation measurement through electromagnetic tracking. We report the static and dynamic results of 11 cases with internal rotation gait (8 male, 3 female, mean age 22.2 years), that underwent FDO with intraoperative electromagnetic tracking and conventional goniometric measurement of the correction. The dynamic and static changes were assessed through three-dimensional gait analysis after a mean of 12 months after surgery and rotational imaging preoperative and after a mean of eleven days postoperatively. Mean hip rotation in stance significantly decreased from 20.9° (SD 5.9) to 5.8° (SD 4.7°) after FDO. The mean amount of derotation quantified by electromagnetic tracking was 23.2° (16.5°-28.8°) and 25.1° (20.0°-33.0°) for goniometric measurement. Both measurement modalities showed small differences to rotational imaging (electromagnetic bone tracking [EMT]: 0.72°; goniometer: 1.19°) but a large deviation when compared to three-dimensional gait analysis (EMT: 8.5°, goniometer: 9.1°). In comparison to the static changes and EMT measurement, the dynamic changes measured during 3-D-gait analysis reflected only 66% of the actual derotation performed during surgery. Although electromagnetic tracking allows a precise intraoperative assessment of the derotation during FDO, the amount of intraoperative correction is not reflected in the improvements in three-dimensional gait analysis.
DOI:doi:10.1002/jor.25168
URL:kostenfrei: Volltext: https://doi.org/10.1002/jor.25168
 kostenfrei: Volltext: https://onlinelibrary.wiley.com/doi/abs/10.1002/jor.25168
 DOI: https://doi.org/10.1002/jor.25168
Datenträger:Online-Ressource
Sprache:eng
Sach-SW:cerebral palsy
 electromagnetic tracking
 femoral derotation
 gait analysis
 internal rotation gait
K10plus-PPN:1855322234
Verknüpfungen:→ Zeitschrift
 
 
Lokale URL UB: Zum Volltext

Permanenter Link auf diesen Titel (bookmarkfähig):  https://katalog.ub.uni-heidelberg.de/titel/69111953   QR-Code
zum Seitenanfang