Titel:Impact of stent design on in-stent stenosis in a rabbit iliac artery model
Verf.angabe:C.M. Sommer, L. Grenacher, U. Stampfl, F.U. Arnegger, C. Rehnitz, H. Thierjung, S. Stampfl, I. Berger, G.M. Richter, H.U. Kauczor, B.A. Radeleff
Jahr:2010
Umfang:11 S.
Fussnoten:Published online: 22 December 2009 ; Gesehen am 14.08.2023
Titel Quelle:Enthalten in: CardioVascular and interventional radiology
Ort Quelle:Berlin : Springer, 1978
Jahr Quelle:2010
Band/Heft Quelle:33(2010), 3, Seite 565-575
ISSN Quelle:1432-086X
Abstract:The purpose of this study was to evaluate the impact of stent design on in-stent stenosis in rabbit iliac arteries. Four different types of stent were implanted in rabbit iliac arteries, being different in stent design (crown or wave) and strut thickness (50 or 100 microm). Ten stents of each type were implanted. Each animal received one crown and one wave stent with the same strut thickness. Follow-up was either 12 weeks (n = 10 rabbits) or 24 weeks (n = 10 rabbits). Primary study end points were angiographic and microscopic in-stent stenosis. Secondary study end points were vessel injury, vascular inflammation, and stent endothelialization. Average stent diameter, relative stent overdilation, average and minimal luminal diameter, and relative average and maximum luminal loss were not significantly different. However, a trend to higher relative stent overdilation was recognized in crown stents compared to wave stents. A trend toward higher average and minimal luminal diameter and lower relative average and maximum luminal loss was recognized in crown stents compared to wave stents with a strut thickness of 100 microm. Neointimal height, relative luminal area stenosis, injury score, inflammation score, and endothelialization score were not significantly different. However, a trend toward higher neointimal height was recognized in crown stents compared to wave stents with a strut thickness of 50 microm and a follow-up of 24 weeks. In conclusion, in this study, crown stents seem to trigger neointima. However, the optimized radial force might equalize the theoretically higher tendency for restenosis in crown stents. In this context, also more favorable positive remodeling in crown stents could be important.
DOI:doi:10.1007/s00270-009-9757-6
URL:Bitte beachten Sie: Dies ist ein Bibliographieeintrag. Ein Volltextzugriff für Mitglieder der Universität besteht hier nur, falls für die entsprechende Zeitschrift/den entsprechenden Sammelband ein Abonnement besteht oder es sich um einen OpenAccess-Titel handelt.

DOI: https://doi.org/10.1007/s00270-009-9757-6
Datenträger:Online-Ressource
Sprache:eng
Sach-SW:Angiography
 Animals
 Disease Models, Animal
 Graft Occlusion, Vascular
 Iliac Artery
 Male
 Prosthesis Design
 Rabbits
 Stents
K10plus-PPN:185613282X
Verknüpfungen:→ Zeitschrift

Permanenter Link auf diesen Titel (bookmarkfähig):  https://katalog.ub.uni-heidelberg.de/titel/69112321   QR-Code
zum Seitenanfang