Navigation überspringen
Universitätsbibliothek Heidelberg
Standort: ---
Exemplare: ---
heiBIB
 Online-Ressource
Verfasst von:Preisner, Fabian [VerfasserIn]   i
 Behnisch, Rouven [VerfasserIn]   i
 Fösleitner, Olivia [VerfasserIn]   i
 Schwarz, Daniel [VerfasserIn]   i
 Wehrstein, Michaela [VerfasserIn]   i
 Meredig, Hagen [VerfasserIn]   i
 Friedmann-Bette, Birgit [VerfasserIn]   i
 Heiland, Sabine [VerfasserIn]   i
 Bendszus, Martin [VerfasserIn]   i
 Kronlage, Moritz [VerfasserIn]   i
Titel:Reliability and reproducibility of sciatic nerve magnetization transfer imaging and T2 relaxometry
Verf.angabe:Fabian Preisner, Rouven Behnisch, Olivia Foesleitner, Daniel Schwarz, Michaela Wehrstein, Hagen Meredig, Birgit Friedmann-Bette, Sabine Heiland, Martin Bendszus, Moritz Kronlage
E-Jahr:2021
Jahr:9 June 2021
Umfang:11 S.
Fussnoten:Gesehen am 15.8.2023
Titel Quelle:Enthalten in: European radiology
Ort Quelle:Berlin : Springer, 1991
Jahr Quelle:2021
Band/Heft Quelle:31(2021), 12, Seite 9120-9130
ISSN Quelle:1432-1084
 1613-3757
Abstract:Objectives To assess the interreader and test-retest reliability of magnetization transfer imaging (MTI) and T2 relaxometry in sciatic nerve MR neurography (MRN). Materials and methods In this prospective study, 21 healthy volunteers were examined three times on separate days by a standardized MRN protocol at 3 Tesla, consisting of an MTI sequence, a multi-echo T2 relaxometry sequence, and a highresolution T2-weighted sequence. Magnetization transfer ratio (MTR), T2 relaxation time, and proton spin density (PSD) of the sciatic nerve were assessed by two independent observers, and both interreader and test-retest reliability for all readout parameters were reported by intraclass correlation coefficients (ICCs) and standard error of measurement (SEM). - Results For the sciatic nerve, overall mean ± standard deviation MTR was 26.75 ± 3.5%, T2 was 64.54 ± 8.2 ms, and PSD was 340.93 ± 78.8. ICCs ranged between 0.81 (MTR) and 0.94 (PSD) for interreader reliability and between 0.75 (MTR) and 0.94 (PSD) for test-retest reliability. SEM for interreader reliability was 1.7% for MTR, 2.67 ms for T2, and 21.3 for PSD. SEM for test-retest reliability was 1.7% for MTR, 2.66 ms for T2, and 20.1 for PSD. - Conclusions MTI and T2 relaxometry of the sciatic nerve are reliable and reproducible. The values of measurement imprecision reported here may serve as a guide for correct interpretation of quantitative MRN biomarkers in future studies. Key Points • Magnetization transfer imaging (MTI) and T2 relaxometry of the sciatic nerve are reliable and reproducible. • The imprecision that is unavoidably associated with different scans or different readers can be estimated by the here presented SEM values for the biomarkers T2, PSD, and MTR. • These values may serve as a guide for correct interpretation of quantitative MRN biomarkers in future studies and possible clinical applications.
DOI:doi:10.1007/s00330-021-08072-9
URL:kostenfrei: Volltext: https://doi.org/10.1007/s00330-021-08072-9
 kostenfrei: Volltext: https://link.springer.com/10.1007/s00330-021-08072-9
 DOI: https://doi.org/10.1007/s00330-021-08072-9
Datenträger:Online-Ressource
Sprache:eng
K10plus-PPN:185621270X
Verknüpfungen:→ Zeitschrift
 
 
Lokale URL UB: Zum Volltext

Permanenter Link auf diesen Titel (bookmarkfähig):  https://katalog.ub.uni-heidelberg.de/titel/69112801   QR-Code
zum Seitenanfang