Online-Ressource | |
Verfasst von: | Zhang, Kevin Sun [VerfasserIn] |
Neelsen, Christian [VerfasserIn] | |
Wennmann, Markus [VerfasserIn] | |
Glemser, Philip [VerfasserIn] | |
Hielscher, Thomas [VerfasserIn] | |
Weru, Vivienn [VerfasserIn] | |
Görtz, Magdalena [VerfasserIn] | |
Schütz, Viktoria [VerfasserIn] | |
Stenzinger, Albrecht [VerfasserIn] | |
Hohenfellner, Markus [VerfasserIn] | |
Schlemmer, Heinz-Peter [VerfasserIn] | |
Bonekamp, David [VerfasserIn] | |
Titel: | Same-day repeatability and between-sequence reproducibility of mean ADC in PI-RADS lesions |
Verf.angabe: | Kevin Sun Zhang, Christian Jan Oliver Neelsen, Markus Wennmann, Philipp Alexander Glemser, Thomas Hielscher, Vivienn Weru, Magdalena Görtz, Viktoria Schütz, Albrecht Stenzinger, Markus Hohenfellner, Heinz-Peter Schlemmer, David Bonekamp |
E-Jahr: | 2023 |
Jahr: | August 2023 |
Umfang: | 11 S. |
Illustrationen: | Illustrationen |
Fussnoten: | Online verfügbar: 8. Juni 2023, Artikelversion: 16. Juni 2023 ; Gesehen am 25.08.2023 |
Titel Quelle: | Enthalten in: European journal of radiology |
Ort Quelle: | Amsterdam [u.a.] : Elsevier Science, 1990 |
Jahr Quelle: | 2023 |
Band/Heft Quelle: | 165(2023) vom: Aug., Artikel-ID 110898, Seite 1-11 |
ISSN Quelle: | 1872-7727 |
Abstract: | Purpose - This study aimed to assess repeatability after repositioning (inter-scan), intra-rater, inter-rater and inter-sequence variability of mean apparent diffusion coefficient (ADC) measurements in MRI-detected prostate lesions. - Method - Forty-three patients with suspicion for prostate cancer were included and received a clinical prostate bi-/multiparametric MRI examination with repeat scans of the T2-weighted and two DWI-weighted sequences (ssEPI and rsEPI). Two raters (R1 and R2) performed single-slice, 2D regions of interest (2D-ROIs) and 3D-segmentation-ROIs (3D-ROIs). Mean bias, corresponding limits of agreement (LoA), mean absolute difference, within-subject coefficient of variation (CoV) and repeatability/reproducibility coefficient (RC/RDC) were calculated. Bradley & Blackwood test was used for variance comparison. Linear mixed models (LMM) were used to account for multiple lesions per patient. - Results - Inter-scan repeatability, intra-rater and inter-sequence reproducibility analysis of ADC showed no significant bias. 3D-ROIs demonstrated significantly less variability than 2D-ROIs (p < 0.01). Inter-rater comparison demonstrated small significant systematic bias of 57 × 10-6 mm2/s for 3D-ROIs (p < 0.001). Intra-rater RC, with the lowest variation, was 145 and 189 × 10-6 mm2/s for 3D- and 2D-ROIs, respectively. For 3D-ROIs of ssEPI, RCs and RDCs were 190-198 × 10-6 mm2/s for inter-scan, inter-rater and inter-sequence variation. No significant differences were found for inter-scan, inter-rater and inter-sequence variability. - Conclusions - In a single-scanner setting, single-slice ADC measurements showed considerable variation, which may be lowered using 3D-ROIs. For 3D-ROIs, we propose a cut-off of ∼ 200 × 10-6 mm2/s for differences introduced by repositioning, rater or sequence effects. The results suggest that follow-up measurements should be possible by different raters or sequences. |
DOI: | doi:10.1016/j.ejrad.2023.110898 |
URL: | Bitte beachten Sie: Dies ist ein Bibliographieeintrag. Ein Volltextzugriff für Mitglieder der Universität besteht hier nur, falls für die entsprechende Zeitschrift/den entsprechenden Sammelband ein Abonnement besteht oder es sich um einen OpenAccess-Titel handelt. Volltext: https://doi.org/10.1016/j.ejrad.2023.110898 |
Volltext: https://www.sciencedirect.com/science/article/pii/S0720048X23002127 | |
DOI: https://doi.org/10.1016/j.ejrad.2023.110898 | |
Datenträger: | Online-Ressource |
Sprache: | eng |
Sach-SW: | ADC |
Apparent diffusion coefficient | |
Prostate | |
Repeatability | |
Reproducibility | |
Retest | |
Stability | |
Test | |
K10plus-PPN: | 1857979559 |
Verknüpfungen: | → Zeitschrift |