Status: Bibliographieeintrag
Standort: ---
Exemplare:
---
| Online-Ressource |
Verfasst von: | Jonas, Jost B. [VerfasserIn]  |
| Jonas, Shefali B. [VerfasserIn]  |
Titel: | Histomorphometry of the circular peripapillary arterial ring of Zinn-Haller in normal eyes and eyes with secondary angle-closure glaucoma |
Verf.angabe: | Jost B. Jonas and Shefali B. Jonas (Department of Ophthalmology, Medical Faculty Mannheim of the Ruprecht-Karls-University of Heidelberg, Heidelberg, Germany) |
E-Jahr: | 2010 |
Jahr: | [December 2010] |
Umfang: | 6 S. |
Illustrationen: | Illustrationen |
Fussnoten: | First published: 14 October 2010 ; Gesehen am 28.08.2023 |
Titel Quelle: | Enthalten in: Acta ophthalmologica |
Ort Quelle: | Oxford : Blackwell, 2008 |
Jahr Quelle: | 2010 |
Band/Heft Quelle: | 88(2010), 8 vom: Dez., Seite e317-e322 |
ISSN Quelle: | 1755-3768 |
Abstract: | Purpose: To examine the location and size of the peripapillary arterial circle of Zinn-Haller (PACZH) and its associations with other eye measures in normal eyes and eyes with secondary angle-closure glaucoma. Methods: The study included 29 human globes enucleated because of malignant choroidal melanoma (n = 19) (control group) or because of secondary angle-closure glaucoma (n = 10). Anterior-posterior histological sections were morphometrically evaluated. Results: The PACZH was present in all eyes. The glaucoma group and the control group did not vary significantly in the distance from the PACZH to Bruch’s membrane (297 ± 67 versus 270 ± 67 μm; p = 0.29), optic disc border (281 ± 103 versus 391 ± 170 μm; p = 0.07), optic disc centre (1059 ± 191 versus 978 ± 205 μm; p = 0.30) and retrobulbar cerebrospinal fluid space (173 ± 58 versus 172 ± 81 μm; p = 0.97) nor in the minimal PACZH diameter (39 ± 18 versus 36 ± 18 μm; p = 0.74) and maximal PACZH diameter (78 ± 37 versus 65 ± 25 μm; p = 0.36). The PACZH location, measured as distance from Bruch’s membrane, disc border, disc centre and cerebrospinal fluid space, was not significantly associated with axial length (p > 0.39), horizontal globe diameter (p > 0.17) and vertical globe diameter (p > 0.22). Both diameters were statistically independent of axial length (p = 0.72 and p = 0.58, respectively), horizontal globe diameter (p = 0.60 and p = 0.41, respectively) and vertical globe diameter (p = 0.64 and p = 0.52, respectively). All parameters were statistically independent of age (p > 0.10) and gender (p > 0.10). Conclusions: The PACZH was present in all human eyes examined and did not vary significantly in location and diameter between eyes with secondary angle-closure glaucoma and nonglaucomatous eyes, nor between myopic versus hyperopic eyes. |
DOI: | doi:10.1111/j.1755-3768.2010.02022.x |
URL: | Bitte beachten Sie: Dies ist ein Bibliographieeintrag. Ein Volltextzugriff für Mitglieder der Universität besteht hier nur, falls für die entsprechende Zeitschrift/den entsprechenden Sammelband ein Abonnement besteht oder es sich um einen OpenAccess-Titel handelt.
Volltext: https://doi.org/10.1111/j.1755-3768.2010.02022.x |
| Volltext: https://onlinelibrary.wiley.com/doi/abs/10.1111/j.1755-3768.2010.02022.x |
| DOI: https://doi.org/10.1111/j.1755-3768.2010.02022.x |
Datenträger: | Online-Ressource |
Sprache: | eng |
Sach-SW: | cerebrospinal fluid |
| circular peripapillary arterial ring Zinn-Haller |
| glaucoma |
| lamina cribrosa |
| optic disc |
K10plus-PPN: | 1858116627 |
Verknüpfungen: | → Zeitschrift |
Histomorphometry of the circular peripapillary arterial ring of Zinn-Haller in normal eyes and eyes with secondary angle-closure glaucoma / Jonas, Jost B. [VerfasserIn]; [December 2010] (Online-Ressource)
69116525