Navigation überspringen
Universitätsbibliothek Heidelberg
Status: Bibliographieeintrag

Verfügbarkeit
Standort: ---
Exemplare: ---
heiBIB
 Online-Ressource
Verfasst von:Qubala, Abdallah [VerfasserIn]   i
 Shafee, Jehad [VerfasserIn]   i
 Batista, Vania [VerfasserIn]   i
 Liermann, Jakob [VerfasserIn]   i
 Winter, Marcus [VerfasserIn]   i
 Piro, Daniel [VerfasserIn]   i
 Jäkel, Oliver [VerfasserIn]   i
Titel:Comparative evaluation of a surface-based respiratory monitoring system against a pressure sensor for 4DCT image reconstruction in phantoms
Verf.angabe:Abdallah Qubala, Jehad Shafee, Vania Batista, Jakob Liermann, Marcus Winter, Daniel Piro, Oliver Jäkel
E-Jahr:2024
Jahr:February 2024
Umfang:14 S.
Illustrationen:Illustrationen
Fussnoten:Online veröffentlicht: 10. Oktober 2023 ; Gesehen am 05.12.2023
Titel Quelle:Enthalten in: Journal of applied clinical medical physics
Ort Quelle:Reston, Va. : ACMP, 2000
Jahr Quelle:2024
Band/Heft Quelle:25(2024), 2, Artikel-ID e14174, Seite 1-14
ISSN Quelle:1526-9914
Abstract:Four-dimensional computed tomography (4DCT), which relies on breathing-induced motion, requires realistic surrogate information of breathing variations to reconstruct the tumor trajectory and motion variability of normal tissues accurately. Therefore, the SimRT surface-guided respiratory monitoring system has been installed on a Siemens CT scanner. This work evaluated the temporal and spatial accuracy of SimRT versus our commonly used pressure sensor, AZ-733 V. A dynamic thorax phantom was used to reproduce regular and irregular breathing patterns acquired by SimRT and Anzai. Various parameters of the recorded breathing patterns, including mean absolute deviations (MAD), Pearson correlations (PC), and tagging precision, were investigated and compared to ground-truth. Furthermore, 4DCT reconstructions were analyzed to assess the volume discrepancy, shape deformation and tumor trajectory. Compared to the ground-truth, SimRT more precisely reproduced the breathing patterns with a MAD range of 0.37 ± 0.27 and 0.92 ± 1.02 mm versus Anzai with 1.75 ± 1.54 and 5.85 ± 3.61 mm for regular and irregular breathing patterns, respectively. Additionally, SimRT provided a more robust PC of 0.994 ± 0.009 and 0.936 ± 0.062 for all investigated breathing patterns. Further, the peak and valley recognition were found to be more accurate and stable using SimRT. The comparison of tumor trajectories revealed discrepancies up to 7.2 and 2.3 mm for Anzai and SimRT, respectively. Moreover, volume discrepancies up to 1.71 ± 1.62% and 1.24 ± 2.02% were found for both Anzai and SimRT, respectively. SimRT was validated across various breathing patterns and showed a more precise and stable breathing tracking, (i) independent of the amplitude and period, (ii) and without placing any physical devices on the patient's body. These findings resulted in a more accurate temporal and spatial accuracy, thus leading to a more realistic 4DCT reconstruction and breathing-adapted treatment planning.
DOI:doi:10.1002/acm2.14174
URL:Bitte beachten Sie: Dies ist ein Bibliographieeintrag. Ein Volltextzugriff für Mitglieder der Universität besteht hier nur, falls für die entsprechende Zeitschrift/den entsprechenden Sammelband ein Abonnement besteht oder es sich um einen OpenAccess-Titel handelt.

kostenfrei: Volltext: https://doi.org/10.1002/acm2.14174
 kostenfrei: Volltext: https://onlinelibrary.wiley.com/doi/abs/10.1002/acm2.14174
 DOI: https://doi.org/10.1002/acm2.14174
Datenträger:Online-Ressource
Sprache:eng
Sach-SW:4DCT reconstruction
 breathing detection
 breathing surrogate
 commissioning
 mobile tumors
 motion artifacts
 respiratory monitoring system
 Surface-guided radiotherapy
K10plus-PPN:187191972X
Verknüpfungen:→ Zeitschrift

Permanenter Link auf diesen Titel (bookmarkfähig):  https://katalog.ub.uni-heidelberg.de/titel/69149500   QR-Code
zum Seitenanfang