Titel:In vitro wear behavior of knee implants at different load levels
Titelzusatz:the impact of the test fluid
Verf.angabe:Stefan Schroeder, Maximilian Uhler, Mareike Schonhoff, Timo A. Nees, Tanja Wonerow, Jens Nuppnau, Frank Mantwill and Jan Philippe Kretzer
E-Jahr:2023
Jahr:4 November 2023
Umfang:12 S.
Illustrationen:Illustrationen
Fussnoten:Gesehen am 19.01.2024
Weitere Titel:Titel des special issue: Tribology of Polymer-Based Composites
Titel Quelle:Enthalten in: Lubricants
Ort Quelle:Basel : MDPI, 2013
Jahr Quelle:2023
Band/Heft Quelle:11(2023), 11, special issue, Artikel-ID 474, Seite 1-12
ISSN Quelle:2075-4442
Abstract:Calf serum is defined as a test fluid for in vitro knee wear simulation studies in the ISO standard. However, protein degradation typically occurs during in vitro wear simulation. The current study should indicate whether increased loads change the rheological properties of the test fluid and may, therefore, lead to favorable tribological behavior and reduced wear. Three different load levels were simulated in a displacement-controlled knee wear simulation study. The gravimetric wear rates were determined, pressure measurements were performed, and the dynamic viscosity of the test fluids were analyzed after the simulation of 0.5 × 106 cycles. The lowest load level led to the lowest wear rate, and the lowest contact pressure and contact area, compared to the medium and high-load level. Although, the high-load level led to the highest contact pressure and contact area, the wear rates were comparable to the medium-load level. The rheological measurements revealed the highest dynamic viscosity for the high-load level and no differences could be found between the medium and low loading condition. To perform realistic wear simulation studies, the reproduction of the in vivo interrelationships between the shear forces and wear are necessary.
DOI:doi:10.3390/lubricants11110474
URL:Bitte beachten Sie: Dies ist ein Bibliographieeintrag. Ein Volltextzugriff für Mitglieder der Universität besteht hier nur, falls für die entsprechende Zeitschrift/den entsprechenden Sammelband ein Abonnement besteht oder es sich um einen OpenAccess-Titel handelt.

kostenfrei: Volltext: https://doi.org/10.3390/lubricants11110474
 kostenfrei: Volltext: https://www.mdpi.com/2075-4442/11/11/474
 DOI: https://doi.org/10.3390/lubricants11110474
Datenträger:Online-Ressource
Sprache:eng
Sach-SW:contact pressure
 knee wear simulation
 polyethylene
 protein degradation
 rheology
 wear
K10plus-PPN:1878545396
Verknüpfungen:→ Zeitschrift

Permanenter Link auf diesen Titel (bookmarkfähig):  https://katalog.ub.uni-heidelberg.de/titel/69163331   QR-Code