Verfasst von:Zhang, Ke [VerfasserIn]   i
 Triphan, Simon M. F. [VerfasserIn]   i
 Wielpütz, Mark Oliver [VerfasserIn]   i
 Ziener, Christian H. [VerfasserIn]   i
 Ladd, Mark E. [VerfasserIn]   i
 Schlemmer, Heinz-Peter [VerfasserIn]   i
 Kauczor, Hans-Ulrich [VerfasserIn]   i
 Kurz, Felix T. [VerfasserIn]   i
 Sedlaczek, Oliver [VerfasserIn]   i
Titel:Simultaneous T1, T2 and T2* mapping of the liver with multi-shot MI-SAGE
Verf.angabe:Ke Zhang, Simon M.F. Triphan, Mark O. Wielpütz, Christian H. Ziener, Mark E. Ladd, Heinz-Peter Schlemmer, Hans-Ulrich Kauczor, Felix T. Kurz, Oliver Sedlaczek
E-Jahr:2024
Jahr:January 2024
Umfang:7 S.
Illustrationen:Illustrationen
Fussnoten:Im Titel sind die Zahlen tiefgestellt ; Online verfügbar: 7. November 2023, Artikelversion: 10. November 2023 ; Gesehen am 25.01.2024
Titel Quelle:Enthalten in: Magnetic resonance imaging
Ort Quelle:Amsterdam [u.a.] : Elsevier Science, 1982
Jahr Quelle:2024
Band/Heft Quelle:105(2024) vom: Jan., Seite 75-81
ISSN Quelle:1873-5894
Abstract:Purpose - To apply multi-shot high-resolution multi inversion spin and gradient echo (MI-SAGE) acquisition for simultaneous liver T1, T2 and T2* mapping. - Methods - Inversion prepared spin- and gradient-echo EPI was developed with ascending slice order across measurements for efficient acquisition with T1, T2, and T2⁎ weighting. Multi-shot EPI was also implemented to minimize distortion and blurring while enabling high in-plane resolution. A dictionary-matching approach was used to fit the images to quantitative parameter maps, which were compared to T1 measured by modified Look-Locker (MOLLI), T1 measured by variable flip angle (VFA), T2 measured by multiple echo time-based Half Fourier Single-shot Turbo spin-Echo (HASTE), T2 measured by radial turbo-spin-echo (rTSE) and T2⁎ measured by multiple gradient echo (MGRE) sequences. - Results - The multi-shot variant of the sequence achieved higher in-plane resolution of 1.7 × 1.7 mm2 with good image quality in 28 s. Derived quantitative maps showed comparable values to conventional mapping methods. As measured in phantom and in vivo, MOLLI, MESE and MGRE give closest values to MISAGE. VFA, HASTE and rTSE show obvious overestimation. - Conclusions - The proposed multi-shot inversion prepared spin- and gradient-echo EPI sequence allows for high-resolution quantitative T1, T2 and T2 liver tissue characterization in a single breath-hold scan.
DOI:doi:10.1016/j.mri.2023.11.004
URL:Bitte beachten Sie: Dies ist ein Bibliographieeintrag. Ein Volltextzugriff für Mitglieder der Universität besteht hier nur, falls für die entsprechende Zeitschrift/den entsprechenden Sammelband ein Abonnement besteht oder es sich um einen OpenAccess-Titel handelt.

kostenfrei: Volltext: https://doi.org/10.1016/j.mri.2023.11.004
 kostenfrei: Volltext: https://www.sciencedirect.com/science/article/pii/S0730725X2300190X
 DOI: https://doi.org/10.1016/j.mri.2023.11.004
Datenträger:Online-Ressource
Sprache:eng
Sach-SW:Liver
 Multi inversion spin and gradient echo
 Multi-shot acquisitions
 Parametric mapping