Navigation überspringen
Universitätsbibliothek Heidelberg
Status: Bibliographieeintrag

Verfügbarkeit
Standort: ---
Exemplare: ---
heiBIB
 Online-Ressource
Verfasst von:Lesch, Carolin [VerfasserIn]   i
 Uhr, Katharina [VerfasserIn]   i
 Vollmer, Matthias [VerfasserIn]   i
 Raschidi, R. [VerfasserIn]   i
 Nessel, Regine [VerfasserIn]   i
 Kallinowski, Friedrich [VerfasserIn]   i
Titel:Standardized suturing can prevent slackening or bursting suture lines in midline abdominal incisions and defects
Institutionen:Technische Universität Hamburg   i
 Technische Universität Hamburg / Institute of Biomechanics   i
Verf.angabe:C. Lesch. K. Uhr, M. Vollmer, R. Raschidi, R. Nessel, F. Kallinowski
Jahr:2022
Umfang:13 S.
Illustrationen:Illustrationen, Diagramme
Fussnoten:Sonstige Körperschaft: Technische Universität Hamburg ; Sonstige Körperschaft: Technische Universität Hamburg, Institute of Biomechanics
Titel Quelle:Enthalten in: Hernia
Ort Quelle:Paris : Springer, 1997
Jahr Quelle:2022
Band/Heft Quelle:26(2022), 6 vom: 23. Aug., Seite 1611-1623
ISSN Quelle:1248-9204
Abstract:Purpose: Incisional hernias often follow open abdominal surgery. A small-stitch–small-bite suture might close the incision durably. We analyzed specific details of this closure technique and assessed their influence on the closure stability. Methods: The effects of cyclic loads, simulating coughs were investigated on a bench test. We prepared porcine bellies in the median line and bovine flanks parallel to the muscle fibers with 15 cm long incisions. Then we punched round or rhomboid defects with a diameter of 5–10 cm into the center of the incision. Monomax® 2–0 and Maxon® 1 and 2–0 were used as suture materials. We tested the durability of the closure with pressure impacts of 210 mmHg repeated 425 times. Throughout the experiments, we modified the suturing technique, the surgeon, the tissue tension, the defect size and shape and the suture diameter. Results: Standardizing the suture technique improved the durability of the closure significantly. Any other variations showed minor influences after standardization. All incisions with round defects up to 7.5 cm width withstood 425 impacts using standardized suturing. Unstandardized sutures failed in all cases. When closing an incision with a 10 cm wide defect, the tissues ruptured frequently next to the suture line. We defined criteria to standardize this suturing technique. For the first time, we developed a suture factor related to the durability of a sutured tissue closure. We integrated the suture factor into the concept of biomechanically durable repairs. Conclusions: Suturing the abdominal wall with a standardized suturing technique improves its durability significantly.
DOI:doi:10.15480/882.4759
URL:Bitte beachten Sie: Dies ist ein Bibliographieeintrag. Ein Volltextzugriff für Mitglieder der Universität besteht hier nur, falls für die entsprechende Zeitschrift/den entsprechenden Sammelband ein Abonnement besteht oder es sich um einen OpenAccess-Titel handelt.

kostenfrei: Resolving-System: http://nbn-resolving.de/urn:nbn:de:gbv:830-882.0201174
 kostenfrei: Resolving-System: https://doi.org/10.15480/882.4759
 kostenfrei: Resolving-System: http://hdl.handle.net/11420/13964
 Resolving-System: https://doi.org/10.1007/s10029-022-02659-x
 DOI: https://doi.org/10.15480/882.4759
 DOI: https://doi.org/10.1007/s10029-022-02659-x
 11420/13964
URN:urn:nbn:de:gbv:830-882.0201174
Datenträger:Online-Ressource
Sprache:eng
K10plus-PPN:1824500084
Verknüpfungen:→ Zeitschrift

Permanenter Link auf diesen Titel (bookmarkfähig):  https://katalog.ub.uni-heidelberg.de/titel/69190767   QR-Code
zum Seitenanfang