Navigation überspringen
Universitätsbibliothek Heidelberg
Status: Bibliographieeintrag

Verfügbarkeit
Standort: ---
Exemplare: ---
heiBIB
 Online-Ressource
Verfasst von:Lenga, Pavlina [VerfasserIn]   i
 Scherer, Moritz [VerfasserIn]   i
 Peretzke, Robin [VerfasserIn]   i
 Neher, Peter [VerfasserIn]   i
 Jesser, Jessica [VerfasserIn]   i
 Beisse, Christina [VerfasserIn]   i
 Unterberg, Andreas [VerfasserIn]   i
 Becker, Daniela Julia Sabine [VerfasserIn]   i
Titel:Correlation of visual field deficits and q-ball high-resolution fiber tractography of the optic radiation for adjacently located intracerebral lesions
Titelzusatz:preliminary results from a single-center prospective study
Verf.angabe:Pavlina Lenga, Moritz Scherer, Robin Peretzke, Peter Neher, Jessica Jesser, Christina Beisse, Andreas W. Unterberg, Daniela Becker
E-Jahr:2024
Jahr:05 January 2024
Umfang:11 S.
Illustrationen:Illustrationen, Diagramme
Fussnoten:Gesehen am 13.05.2024
Titel Quelle:Enthalten in: Neurosurgical review
Ort Quelle:Berlin : Springer, 1978
Jahr Quelle:2024
Band/Heft Quelle:47(2024), 1, Artikel-ID 31, Seite 1-11
ISSN Quelle:1437-2320
Abstract:Visual field deficits (VFDs) are common in patients with temporal and occipital lobe lesions. Diffusion tensor fiber tractography (DTI-FT) is widely used for surgery planning to reduce VFDs. Q-ball high-resolution fiber tractography (QBI-HRFT) improves upon DTI. This study aims to evaluate the effectiveness of DTI-FT and QBI-HRFT for surgery planning near the optic radiation (OR) as well as the correlation between VFDs, the nearest distance from the lesion to the OR fiber bundle (nD-LOR), and the lesion volume (LV). This ongoing prospective clinical trial collects clinical and imaging data of patients with lesions in deterrent areas. The present subanalysis included eight patients with gliomas near the OR. Probabilistic HRFT based on QBI-FT and conventional DTI-FT were performed for OR reconstruction based on a standard diffusion-weighted magnetic resonance imaging sequence in clinical use. Quantitative analysis was used to evaluate the lesion volume (LV) and nD-LOR. VFDs were determined based on standardized automated perimetry. We included eight patients (mean age 51.7 years [standard deviation (SD) 9.5]) with lesions near the OR. Among them, five, two, and one patients had temporodorsal, occipital, and temporal lesions, respectively. Four patients had normal vision preoperatively, while four patients had preexisting VFD. QBI-FT analysis indicated that patients with VFD exhibited a significantly smaller median nD-LOR (mean, −4.5; range −7.0; −2.3) than patients without VFD (mean, 7.4; range −4.3; 27.2) (p = 0.050). There was a trend towards a correlation between tumor volume and nD-LOR when QBI-FT was used (rs = −0.6; p = 0.056). A meticulous classification of the spatial relationship between the lesions and OR according to DTI-FT and QBI-FT was performed. The results indicated that the most prevalent orientations were the FT bundles located laterally and intrinsically in relation to the tumor. Compared with conventional DTI-FT, QBI-FT suggests reliable and more accurate results when correlated to preoperative VFDs and might be preferred for preoperative planning and intraoperative use of nearby lesions, particularly for those with larger volumes. A detailed analysis of localization, surgical approach together with QBI-FT and DTI-FT could reduce postoperative morbidity regarding VFDs. The display of HRFT techniques intraoperatively within the navigation system should be pursued for this issue.
DOI:doi:10.1007/s10143-023-02278-9
URL:Bitte beachten Sie: Dies ist ein Bibliographieeintrag. Ein Volltextzugriff für Mitglieder der Universität besteht hier nur, falls für die entsprechende Zeitschrift/den entsprechenden Sammelband ein Abonnement besteht oder es sich um einen OpenAccess-Titel handelt.

Volltext: https://doi.org/10.1007/s10143-023-02278-9
 DOI: https://doi.org/10.1007/s10143-023-02278-9
Datenträger:Online-Ressource
Sprache:eng
Sach-SW:Diffusion tensor imaging
 Fiber tracking
 High-resolution fiber tractography
 Optic radiation
 Q-ball imaging
 Visual field deficits
K10plus-PPN:1888395338
Verknüpfungen:→ Zeitschrift

Permanenter Link auf diesen Titel (bookmarkfähig):  https://katalog.ub.uni-heidelberg.de/titel/69212962   QR-Code
zum Seitenanfang