Navigation überspringen
Universitätsbibliothek Heidelberg
Status: Bibliographieeintrag

Verfügbarkeit
Standort: ---
Exemplare: ---
heiBIB
 Online-Ressource
Verfasst von:Tovia-Brodie, Oholi [VerfasserIn]   i
 Rav Acha, Moshe [VerfasserIn]   i
 Belhassen, Bernard [VerfasserIn]   i
 Gasperetti, Alessio [VerfasserIn]   i
 Schiavone, Marco [VerfasserIn]   i
 Forleo, Giovanni Battista [VerfasserIn]   i
 Guevara-Valdivia, Milton E. [VerfasserIn]   i
 Ruiz, David Valdeolivar [VerfasserIn]   i
 Lellouche, Nicolas [VerfasserIn]   i
 Hamon, David [VerfasserIn]   i
 Castagno, Davide [VerfasserIn]   i
 Bellettini, Matteo [VerfasserIn]   i
 De Ferrari, Gaetano M. [VerfasserIn]   i
 Laredo, Mikael [VerfasserIn]   i
 Carvès, Jean-Baptiste [VerfasserIn]   i
 Ignatiuk, Barbara [VerfasserIn]   i
 Pasquetto, Giampaolo [VerfasserIn]   i
 De Filippo, Paolo [VerfasserIn]   i
 Malanchini, Giovanni [VerfasserIn]   i
 Pavri, Behzad B. [VerfasserIn]   i
 Raphael, Craig [VerfasserIn]   i
 Rivetti, Luigi [VerfasserIn]   i
 Mantovan, Roberto [VerfasserIn]   i
 Chinitz, Jason [VerfasserIn]   i
 Harding, Melissa [VerfasserIn]   i
 Boriani, Giuseppe [VerfasserIn]   i
 Casali, Edoardo [VerfasserIn]   i
 Wan, Elaine Y. [VerfasserIn]   i
 Biviano, Angelo [VerfasserIn]   i
 Macias, Carlos [VerfasserIn]   i
 Havranek, Stepan [VerfasserIn]   i
 Lazzerini, Pietro Enea [VerfasserIn]   i
 Canu, Antonio M. [VerfasserIn]   i
 Zardini, Marco [VerfasserIn]   i
 Conte, Giulio [VerfasserIn]   i
 Cano, Óscar [VerfasserIn]   i
 Casella, Michela [VerfasserIn]   i
 Rudic, Boris [VerfasserIn]   i
 Omelchenko, Alexander [VerfasserIn]   i
 Mathuria, Nilesh [VerfasserIn]   i
 Upadhyay, Gaurav A. [VerfasserIn]   i
 Danon, Asaf [VerfasserIn]   i
 Schwartz, Arie Lorin [VerfasserIn]   i
 Maury, Philippe [VerfasserIn]   i
 Nakahara, Shiro [VerfasserIn]   i
 Goldenberg, Gustavo [VerfasserIn]   i
 Schaerli, Nicolas [VerfasserIn]   i
 Bereza, Sergiy [VerfasserIn]   i
 Auricchio, Angelo [VerfasserIn]   i
 Glikson, Michael [VerfasserIn]   i
 Michowitz, Yoav [VerfasserIn]   i
Titel:Implantation of cardiac electronic devices in active COVID-19 patients
Titelzusatz:results from an international survey
Verf.angabe:Oholi Tovia-Brodie, Moshe Rav Acha, Bernard Belhassen, Alessio Gasperetti, Marco Schiavone, Giovanni Battista Forleo, Milton E. Guevara-Valdivia, David Valdeolivar Ruiz, Nicolas Lellouche, David Hamon, Davide Castagno, Matteo Bellettini, Gaetano M. De Ferrari, Mikael Laredo, Jean-Baptiste Carvès, Barbara Ignatiuk, Giampaolo Pasquetto, Paolo De Filippo, Giovanni Malanchini, Behzad B. Pavri, Craig Raphael, Luigi Rivetti, Roberto Mantovan, Jason Chinitz, Melissa Harding, Giuseppe Boriani, Edoardo Casali, Elaine Y. Wan, Angelo Biviano, Carlos Macias, Stepan Havranek, Pietro Enea Lazzerini, Antonio M. Canu, Marco Zardini, Giulio Conte, Óscar Cano, Michela Casella, Boris Rudic, Alexander Omelchenko, Nilesh Mathuria, Gaurav A. Upadhyay, Asaf Danon, Arie Lorin Schwartz, Philippe Maury, Shiro Nakahara, Gustavo Goldenberg, Nicolas Schaerli, Sergiy Bereza, Angelo Auricchio, Michael Glikson, Yoav Michowitz
E-Jahr:2022
Jahr:February 2022
Umfang:11 S.
Fussnoten:Online verfügbar: 26. Oktober 2021, Artikelversion: 28. Januar 2022 ; Gesehen am 28.05.2024
Titel Quelle:Enthalten in: Heart rhythm
Ort Quelle:New York, NY [u.a.] : Elsevier, 2004
Jahr Quelle:2022
Band/Heft Quelle:19(2022), 2 vom: Feb., Seite 206-216
ISSN Quelle:1556-3871
Abstract:Background - Cardiac implantable electronic device (CIED) implantation rates as well as the clinical and procedural characteristics and outcomes in patients with known active coronavirus disease 2019 (COVID-19) are unknown. - Objective - The purpose of this study was to gather information regarding CIED procedures during active COVID-19, performed with personal protective equipment, based on an international survey. - Methods - Fifty-three centers from 13 countries across 4 continents provided information on 166 patients with known active COVID-19 who underwent a CIED procedure. - Results - The CIED procedure rate in 133,655 hospitalized COVID-19 patients ranged from 0 to 16.2 per 1000 patients (P <.001). Most devices were implanted due to high-degree/complete atrioventricular block (112 [67.5%]) or sick sinus syndrome (31 [18.7%]). Of the 166 patients in the study survey, the 30-day complication rate was 13.9% and the 180-day mortality rate was 9.6%. One patient had a fatal outcome as a direct result of the procedure. Differences in patient and procedural characteristics and outcomes were found between Europe and North America. An older population (76.6 vs 66 years; P <.001) with a nonsignificant higher complication rate (16.5% vs 7.7%; P = .2) was observed in Europe vs North America, whereas higher rates of critically ill patients (33.3% vs 3.3%; P <.001) and mortality (26.9% vs 5%; P = .002) were observed in North America vs Europe. - Conclusion - CIED procedure rates during known active COVID-19 disease varied greatly, from 0 to 16.2 per 1000 hospitalized COVID-19 patients worldwide. Patients with active COVID-19 infection who underwent CIED implantation had high complication and mortality rates. Operators should take these risks into consideration before proceeding with CIED implantation in active COVID-19 patients.
DOI:doi:10.1016/j.hrthm.2021.10.020
URL:Bitte beachten Sie: Dies ist ein Bibliographieeintrag. Ein Volltextzugriff für Mitglieder der Universität besteht hier nur, falls für die entsprechende Zeitschrift/den entsprechenden Sammelband ein Abonnement besteht oder es sich um einen OpenAccess-Titel handelt.

Volltext: https://doi.org/10.1016/j.hrthm.2021.10.020
 Volltext: https://www.sciencedirect.com/science/article/pii/S1547527121023110
 DOI: https://doi.org/10.1016/j.hrthm.2021.10.020
Datenträger:Online-Ressource
Sprache:eng
Sach-SW:Active COVID-19
 Cardiac implantable electronic device procedure
 Complications
 Mortality
 Personal protective equipment
K10plus-PPN:1890029602
Verknüpfungen:→ Zeitschrift

Permanenter Link auf diesen Titel (bookmarkfähig):  https://katalog.ub.uni-heidelberg.de/titel/69218065   QR-Code
zum Seitenanfang