Navigation überspringen
Universitätsbibliothek Heidelberg
Status: Bibliographieeintrag

Verfügbarkeit
Standort: ---
Exemplare: ---
heiBIB
 Online-Ressource
Verfasst von:Bömicke, Wolfgang [VerfasserIn]   i
 Rammelsberg, Peter [VerfasserIn]   i
 Spatola, Gianluca [VerfasserIn]   i
 Rues, Stefan [VerfasserIn]   i
Titel:The effect of titanium anodization on the bond strength of 10-methacryloyloxydecyl dihydrogen phosphate (10-MDP) resin cement
Verf.angabe:Wolfgang Bömicke, Peter Rammelsberg, Gianluca Spatola, Stefan Rues
E-Jahr:2023
Jahr:December 18, 2023
Umfang:10 S.
Fussnoten:Gesehen am 12.07.2024
Titel Quelle:Enthalten in: The international journal of prosthodontics
Ort Quelle:Batavia : Quintessence Publishing, 1988
Jahr Quelle:2023
Band/Heft Quelle:36(2023), 6, Seite E133-E142
ISSN Quelle:1942-4426
Abstract:Purpose: To examine the effects of anodization and different surface modifications of titanium on bond strength to 10-methacryloyloxydecyl dihydrogen phosphate (10-MDP) resin cement. Materials and Methods: Grade 5 titanium alloy disks (n = 160) were assigned to one of five prebonding surface treatment study groups (polished; polished and anodized; polished, etched, and anodized; sandblasted; sandblasted and anodized). Disks were adhesively bonded with 10-MDP resin cement (Panavia 21; bonding area: 3.3 mm in diameter) to composite resin cylinders. In each study group, tensile bond strength tests were conducted after 24 ± 1 hours and after 6 months (180 ± 2 days) of water storage (n = 16 specimens per water storage subgroup). Debonded specimens were stereomicroscopically analyzed to determine their fracture mode. Statistics included one-way and multifactorial ANOVA and Tukey post hoc tests (α = .05). Results: Anodization and water storage did not significantly (P ≥ .389) affect tensile bond strength. Although subgroups of polished samples had significantly (P ≤ .031) lower bond strengths (subgroup mean values: 20 to 26 MPa) than etched or sandblasted samples (subgroup mean values: 29 to 33 MPa), they nonetheless exceeded the empirical threshold of 10 MPa used as a criterion for clinical recommendation. The fracture mode of all test specimens was predominantly cohesive. Conclusions: Anodization of titanium surfaces can be performed without weakening the adhesion of 10-MDP–based resin cement to titanium.
DOI:doi:10.11607/ijp.7821
URL:Bitte beachten Sie: Dies ist ein Bibliographieeintrag. Ein Volltextzugriff für Mitglieder der Universität besteht hier nur, falls für die entsprechende Zeitschrift/den entsprechenden Sammelband ein Abonnement besteht oder es sich um einen OpenAccess-Titel handelt.

Volltext: https://www.quintessence-publishing.com/usa/en/article/4784773/the-international-journal-of-prosthodontics/2023/06/the-e ...
 Volltext: https://dx.doi.org/10.11607/ijp.7821
 DOI: https://doi.org/10.11607/ijp.7821
Datenträger:Online-Ressource
Sprache:eng
K10plus-PPN:1895218098
Verknüpfungen:→ Zeitschrift

Permanenter Link auf diesen Titel (bookmarkfähig):  https://katalog.ub.uni-heidelberg.de/titel/69233052   QR-Code
zum Seitenanfang