Titel: | The effect of titanium anodization on the bond strength of 10-methacryloyloxydecyl dihydrogen phosphate (10-MDP) resin cement |
Verf.angabe: | Wolfgang Bömicke, Peter Rammelsberg, Gianluca Spatola, Stefan Rues |
E-Jahr: | 2023 |
Jahr: | December 18, 2023 |
Umfang: | 10 S. |
Fussnoten: | Gesehen am 12.07.2024 |
Titel Quelle: | Enthalten in: The international journal of prosthodontics |
Ort Quelle: | Batavia : Quintessence Publishing, 1988 |
Jahr Quelle: | 2023 |
Band/Heft Quelle: | 36(2023), 6, Seite E133-E142 |
ISSN Quelle: | 1942-4426 |
Abstract: | Purpose: To examine the effects of anodization and different surface modifications of titanium on bond strength to 10-methacryloyloxydecyl dihydrogen phosphate (10-MDP) resin cement. Materials and Methods: Grade 5 titanium alloy disks (n = 160) were assigned to one of five prebonding surface treatment study groups (polished; polished and anodized; polished, etched, and anodized; sandblasted; sandblasted and anodized). Disks were adhesively bonded with 10-MDP resin cement (Panavia 21; bonding area: 3.3 mm in diameter) to composite resin cylinders. In each study group, tensile bond strength tests were conducted after 24 ± 1 hours and after 6 months (180 ± 2 days) of water storage (n = 16 specimens per water storage subgroup). Debonded specimens were stereomicroscopically analyzed to determine their fracture mode. Statistics included one-way and multifactorial ANOVA and Tukey post hoc tests (α = .05). Results: Anodization and water storage did not significantly (P ≥ .389) affect tensile bond strength. Although subgroups of polished samples had significantly (P ≤ .031) lower bond strengths (subgroup mean values: 20 to 26 MPa) than etched or sandblasted samples (subgroup mean values: 29 to 33 MPa), they nonetheless exceeded the empirical threshold of 10 MPa used as a criterion for clinical recommendation. The fracture mode of all test specimens was predominantly cohesive. Conclusions: Anodization of titanium surfaces can be performed without weakening the adhesion of 10-MDP–based resin cement to titanium. |
DOI: | doi:10.11607/ijp.7821 |
URL: | Bitte beachten Sie: Dies ist ein Bibliographieeintrag. Ein Volltextzugriff für Mitglieder der Universität besteht hier nur, falls für die entsprechende Zeitschrift/den entsprechenden Sammelband ein Abonnement besteht oder es sich um einen OpenAccess-Titel handelt.
Volltext: https://www.quintessence-publishing.com/usa/en/article/4784773/the-international-journal-of-prosthodontics/2023/06/the-e ... |
| Volltext: https://dx.doi.org/10.11607/ijp.7821 |
| DOI: https://doi.org/10.11607/ijp.7821 |
Datenträger: | Online-Ressource |
Sprache: | eng |
K10plus-PPN: | 1895218098 |
Verknüpfungen: | → Zeitschrift |
¬The¬ effect of titanium anodization on the bond strength of 10-methacryloyloxydecyl dihydrogen phosphate (10-MDP) resin cement / Bömicke, Wolfgang [VerfasserIn]; December 18, 2023 (Online-Ressource)
69233052