Titel:In vitro testing of a funnel-tip catheter with different clot types to decrease clot migration in mechanical thrombectomy
Verf.angabe:Emily S. Payne, Samantha Krost-Reuhl, Axel Heimann, Naureen Keric, Julia Masomi-Bornwasser, Tiemo Gerber, Larissa Seidman, Stefanie Kirschner, Marc A. Brockmann and Yasemin Tanyildizi
E-Jahr:2023
Jahr:Dec 2023
Umfang:11 S.
Fussnoten:Erstmals online veröffentlicht: 1. September 2022 ; Gesehen am 16.07.2024
Titel Quelle:Enthalten in: Interventional neuroradiology
Ort Quelle:London : Sage Publishing, 1995
Jahr Quelle:2023
Band/Heft Quelle:29(2023), 6 vom: Dez., Seite 637-647
ISSN Quelle:2385-2011
Abstract:Background - Mechanical thrombectomy is the standard treatment for acute ischemic stroke in patients with large vessel occlusion and can be performed up to 24h after symptom onset. Despite high recanalization rates, embolism in new territories has been reported in 8.6% of the cases. Causes for this could be clot abruption during stent retrieval into the smaller opening of a standard distal access catheter, and antegrade blood flow via collaterals despite proximal balloon protection. A funnel-shaped tip with a larger internal diameter was developed to increase the rate of first-pass recanalization and to improve the safety and efficacy of mechanical thrombectomy. - Methods - This in vitro study compared the efficacy of a funnel-shaped tip with a standard tip in combination with different clot compositions. Mechanical thrombectomy was performed 80 times for each tip, using two stent retrievers (Trevo XP ProVue 3/20 mm, 4/20 mm) and four different clot types (hard vs. soft clots, 0-24h vs. 72h aged clots). - Results - Significantly higher first-pass recanalization rates (mTICI 3) were observed for the funnel-shaped tip, 70.0% versus 30.0% for the standard tip (absolute difference, 32; relative difference 57.1%; P < .001), regardless of the clot type and stent retriever. Recanalization could be increased using harder Chandler loop clots versus softer statically generated clots, as well as 0-24h versus 72h aged clots, respectively. - Conclusion - The funnel-shaped tip achieved higher first-pass recanalization rates than the smaller standard tip and lower rates of clot abruption at the tip. Clot compositions and aging times impacted recanalization rates.
DOI:doi:10.1177/15910199221122843
URL:Bitte beachten Sie: Dies ist ein Bibliographieeintrag. Ein Volltextzugriff für Mitglieder der Universität besteht hier nur, falls für die entsprechende Zeitschrift/den entsprechenden Sammelband ein Abonnement besteht oder es sich um einen OpenAccess-Titel handelt.

Volltext: https://doi.org/10.1177/15910199221122843