Titel:Influence of heart rate and heart rate variability on the feasibility of ultra-fast, high-pitch coronary photon-counting computed tomography angiography
Verf.angabe:Lukas T. Rotkopf, Matthias F. Froelich, Philipp Riffel, Christian H. Ziener, Carissa Reid, Heinz-Peter Schlemmer, Stefan O. Schoenberg, Isabelle Ayx
E-Jahr:2023
Jahr:May 2023
Umfang:9 S.
Illustrationen:Illustrationen
Fussnoten:Online veröffentlicht: 11. Februar 2023 ; Gesehen am 12.08.2024
Titel Quelle:Enthalten in: The international journal of cardiovascular imaging
Ort Quelle:Dordrecht [u.a.] : Springer, 2001
Jahr Quelle:2023
Band/Heft Quelle:39(2023), 5, Seite 1065-1073
ISSN Quelle:1875-8312
Abstract:Coronary computed tomography angiography has become a mainstay in diagnosing coronary artery disease and is increasingly used in screening symptomatic patients. Recently, photon-counting computed tomography (PCCT) has been introduced into clinical practice, offering higher spatial and temporal resolution. As the applied radiation dose is highly dependent on the choice of scan mode and is lowest using the ultra-fast high-pitch (FLASH) mode, guidelines for their application are needed. From a retrospective study investigating the properties of a novel photon-counting computed tomography, all patients who underwent FLASH-mode PCCT angiography were selected between January and April 2022. This resulted in a study population of 46 men and 27 women. We recorded pre- and intrascan ECG readings and calculated heart rate (maximum heart rate 73 bpm) as well heart rate variability (maximum HRV 37 bpm) as measured by the standard deviation of the heart rate. Diagnostic quality and motion artifacts scores were recorded for each coronary artery segment by consensus between two readers. We found a highly significant association between heart rate variability and image quality (p < 0.001). The heart rate itself was not independently associated with image quality. Both heart rate and heart rate variability were significantly associated with the presence of motion artifacts in a combined model. Scan heart rate variability—but not heart rate itself—is a highly significant predictor of reduced image quality on high-pitch coronary photon-counting computed tomography angiography. This may be due to better scanner architecture and an increased temporal resolution compared to conventional energy-integrating detector computed tomography, which has to be addressed in a comparison study in the future.
DOI:doi:10.1007/s10554-023-02808-y
URL:Bitte beachten Sie: Dies ist ein Bibliographieeintrag. Ein Volltextzugriff für Mitglieder der Universität besteht hier nur, falls für die entsprechende Zeitschrift/den entsprechenden Sammelband ein Abonnement besteht oder es sich um einen OpenAccess-Titel handelt.

kostenfrei: Volltext: https://doi.org/10.1007/s10554-023-02808-y
 kostenfrei: Volltext: https://link.springer.com/article/10.1007/s10554-023-02808-y
 DOI: https://doi.org/10.1007/s10554-023-02808-y
Datenträger:Online-Ressource
Sprache:eng
Sach-SW:Dose reduction
 FLASH mode
 Heart rate
 Image quality