Navigation überspringen
Universitätsbibliothek Heidelberg
Status: Bibliographieeintrag

Verfügbarkeit
Standort: ---
Exemplare: ---
heiBIB
 Online-Ressource
Verfasst von:Zadeh, Ehsan Safai [VerfasserIn]   i
 Görg, Mathis [VerfasserIn]   i
 Görg, Christian [VerfasserIn]   i
 Prosch, Helmut [VerfasserIn]   i
 Trenker, Corinna [VerfasserIn]   i
 Westhoff, Christina Carolin [VerfasserIn]   i
 Dietrich, Christoph F. [VerfasserIn]   i
 Raab, Nils [VerfasserIn]   i
 Alhyari, Amjad [VerfasserIn]   i
 Huber, Katharina Paulina [VerfasserIn]   i
 Pochepnia, Svitlana [VerfasserIn]   i
 Weber, Michael [VerfasserIn]   i
 Findeisen, Hajo [VerfasserIn]   i
Titel:The value of contrast-enhanced ultrasound in percutaneous biopsy of retroperitoneal masses
Paralleltitel:Der Stellenwert des kontrastverstärkten Ultraschalls bei der perkutanen Biopsie retroperitonealer Raumforderungen
Verf.angabe:Ehsan Safai Zadeh, Mathis Görg, Christian Görg, Helmut Prosch, Corinna Trenker, Christina Carolin Westhoff, Christoph F. Dietrich, Nils Raab, Amjad Alhyari, Katharina Huber, Svitlana Pochepnia, Michael Weber, Hajo Findeisen
Jahr:2025
Umfang:7 S.
Illustrationen:Illustrationen
Fussnoten:Gesehen am 16.09.2024
Titel Quelle:Enthalten in: Ultraschall in der Medizin
Ort Quelle:Stuttgart [u.a.] : Thieme, 1980
Jahr Quelle:2025
Band/Heft Quelle:46(2025), 1, Seite 66-72
ISSN Quelle:1438-8782
Abstract:Purpose: To evaluate the diagnostic yield of contrast-enhanced ultrasound (CEUS)-guided biopsy of retroperitoneal masses (RMs). Materials and Methods: Between 2006 and 2023, 87 patients presented at our US center for biopsy of an RM. In all biopsies, CEUS was performed prior to the intervention. The technical success rate of biopsy, the presence of diagnostic tissue in solid tumor biopsy samples, the accuracy of the biopsy and the occurrence of post-interventional complications were evaluated. Results: A US-guided biopsy could be conducted in 84/87 cases (96.6%). In 3/87 cases (3.4%), US-guided biopsy was impossible because the planned needle path was obstructed by vital structures. Of 84 lesions, 80 (95.2%) were solid lesions, and 4 (4.8%) were lesions containing fluid. In all solid tumors, 80/80 (100%), diagnostic vital tissue was successfully obtained. CEUS-guided biopsy showed a sensitivity of 93.2%, a specificity of 100%, a positive predictive value of 100%, a negative predictive value of 72.2%, and a diagnostic accuracy of 94.2% for the differentiation between malignant and benign RMs. In one of the 84 cases (1.2%), there was a complication of postinterventional abdominal pain. Conclusion: Percutaneous CEUS-guided biopsy is a safe procedure with a high diagnostic yield and a low complication rate.</p>
DOI:doi:10.1055/a-2282-2353
URL:Bitte beachten Sie: Dies ist ein Bibliographieeintrag. Ein Volltextzugriff für Mitglieder der Universität besteht hier nur, falls für die entsprechende Zeitschrift/den entsprechenden Sammelband ein Abonnement besteht oder es sich um einen OpenAccess-Titel handelt.

kostenfrei: Volltext: https://doi.org/10.1055/a-2282-2353
 kostenfrei: Volltext: http://www.thieme-connect.de/DOI/DOI?10.1055/a-2282-2353
 DOI: https://doi.org/10.1055/a-2282-2353
Datenträger:Online-Ressource
Sprache:eng
K10plus-PPN:190257950X
Verknüpfungen:→ Zeitschrift

Permanenter Link auf diesen Titel (bookmarkfähig):  https://katalog.ub.uni-heidelberg.de/titel/69253607   QR-Code
zum Seitenanfang