Navigation überspringen
Universitätsbibliothek Heidelberg
Status: Bibliographieeintrag

Verfügbarkeit
Standort: ---
Exemplare: ---
heiBIB
 Online-Ressource
Verfasst von:Meißner, Tobias [VerfasserIn]   i
 Rozhkov, V. [VerfasserIn]   i
 Hesser, Jürgen [VerfasserIn]   i
 Nahm, W. [VerfasserIn]   i
 Löw, Nikolas [VerfasserIn]   i
Titel:Quantitative comparison of planar coded aperture imaging reconstruction methods
Verf.angabe:T. Meißner, V. Rozhkov, J. Hesser, W. Nahm, N. Loew
E-Jahr:2023
Jahr:10 January 2023
Umfang:23 S.
Fussnoten:Gesehen am 30.09.2024
Titel Quelle:Enthalten in: Journal of Instrumentation
Ort Quelle:London : Inst. of Physics, 2006
Jahr Quelle:2023
Band/Heft Quelle:18(2023), 01, Artikel-ID P01006, Seite 1-23
ISSN Quelle:1748-0221
Abstract:Imaging distributions of radioactive sources plays a substantial role in nuclear medicine as well as in monitoring nuclear waste and its deposit. Coded Aperture Imaging (CAI) has been proposed as an alternative to parallel or pinhole collimators, but requires image reconstruction as an extra step. Multiple reconstruction methods with varying run time and computational complexity have been proposed. Yet, no quantitative comparison between the different reconstruction methods has been carried out so far. This paper focuses on a comparison based on three sets of hot-rod phantom images captured with an experimental γ-camera consisting of a Tungsten-based MURA mask with a 2 mm thick 256 × 256 pixelated CdTe semiconductor detector coupled to a Timepix© readout circuit. Analytical reconstruction methods, MURA Decoding, Wiener Filter and a convolutional Maximum Likelihood Expectation Maximization (MLEM) algorithm were compared to data-driven Convolutional Encoder-Decoder (CED) approaches. The comparison is based on the contrast-to-noise ratio as it has been previously used to assess reconstruction quality. For the given set-up, MURA Decoding, the most commonly used CAI reconstruction method, provides robust reconstructions despite the assumption of a linear model. For single image reconstruction, however, MLEM performed best of all analytical reconstruction methods, but took on average 45 times longer than MURA Decoding. The fastest reconstruction method is the Wiener Filter with a run time 4.3 times faster compared to MURA Decoding and a mediocre quality. The CED with a specifically tailored training set was able to succeed the most commonly used MURA decoding on average by a factor between 1.37 and 2.60 and an equal run time.
DOI:doi:10.1088/1748-0221/18/01/P01006
URL:Bitte beachten Sie: Dies ist ein Bibliographieeintrag. Ein Volltextzugriff für Mitglieder der Universität besteht hier nur, falls für die entsprechende Zeitschrift/den entsprechenden Sammelband ein Abonnement besteht oder es sich um einen OpenAccess-Titel handelt.

kostenfrei: Volltext: https://doi.org/10.1088/1748-0221/18/01/P01006
 kostenfrei: Volltext: https://dx.doi.org/10.1088/1748-0221/18/01/P01006
 DOI: https://doi.org/10.1088/1748-0221/18/01/P01006
Datenträger:Online-Ressource
Sprache:eng
K10plus-PPN:1903771943
Verknüpfungen:→ Zeitschrift

Permanenter Link auf diesen Titel (bookmarkfähig):  https://katalog.ub.uni-heidelberg.de/titel/69257361   QR-Code
zum Seitenanfang