Navigation überspringen
Universitätsbibliothek Heidelberg
Status: Bibliographieeintrag

Verfügbarkeit
Standort: ---
Exemplare: ---
heiBIB
 Online-Ressource
Verfasst von:Schuppert, Christopher [VerfasserIn]   i
 Salatzki, Janek [VerfasserIn]   i
 André, Florian [VerfasserIn]   i
 Riffel, Johannes [VerfasserIn]   i
 Mangold, David Lukas [VerfasserIn]   i
 Melzig, Claudius [VerfasserIn]   i
 Hagar, Muhammad Taha [VerfasserIn]   i
 Kauczor, Hans-Ulrich [VerfasserIn]   i
 Weber, Tim [VerfasserIn]   i
 Rengier, Fabian [VerfasserIn]   i
 Do, Thuy [VerfasserIn]   i
Titel:Feasibility of reduced iodine loads for vascular assessment prior to transcatheter aortic valve implantation (TAVI) using spectral detector CT
Verf.angabe:Christopher Schuppert, Janek Salatzki, Florian André, Johannes Riffel, David L. Mangold, Claudius Melzig, Muhammad Taha Hagar, Hans-Ulrich Kauczor, Tim F. Weber, Fabian Rengier, Thuy D. Do
E-Jahr:2024
Jahr:24 April 2024
Umfang:15 S.
Fussnoten:Gesehen am 30.09.2024
Titel Quelle:Enthalten in: Diagnostics
Ort Quelle:Basel : MDPI, 2011
Jahr Quelle:2024
Band/Heft Quelle:14(2024), 9, Artikel-ID 879, Seite 879-1-879-15
ISSN Quelle:2075-4418
Abstract:Reduced iodine loads for computed tomography (CT)-based vascular assessment prior to transcatheter aortic valve implantation (TAVI) may be feasible in conjunction with a spectral detector CT scanner. This prospective single-center study considered 100 consecutive patients clinically referred for pre-TAVI CT. They were examined on a dual-layer detector CT scanner to obtain an ECG-gated cardiac scan and a non-ECG-gated aortoiliofemoral scan. Either a standard contrast media (SCM) protocol using 80 mL Iohexol 350 mgI/mL (iodine load: 28 gI) or a body-mass-index adjusted reduced contrast media (RCM) protocol using 40-70 mL Iohexol 350 mgI/mL (iodine load: 14-24.5 gI) were employed. Conventional images and virtual monoenergetic images at 40-80 keV were reconstructed. A threshold of 250 HU was set for sufficient attenuation along the arterial access pathway. A qualitative assessment used a five-point Likert scale. Sufficient attenuation in the thoracic aorta was observed for all patients in both groups using conventional images. In the abdominal, iliac, and femoral segments, sufficient attenuation was observed for the majority of patients when using virtual monoenergetic images (SCM: 96-100% of patients, RCM: 88-94%) without statistical difference between both groups. Segments with attenuation measurements below the threshold remained qualitatively assessable as well. Likert scores were ‘excellent’ for virtual monoenergetic images 50 keV and 55 keV in both groups (RCM: 1.2-1.4, SCM: 1.2-1.3). With diagnostic image quality maintained, it can be concluded that reduced iodine loads of 14-24.5 gI are feasible for pre-TAVI vascular assessment on a spectral detector CT scanner.
DOI:doi:10.3390/diagnostics14090879
URL:Bitte beachten Sie: Dies ist ein Bibliographieeintrag. Ein Volltextzugriff für Mitglieder der Universität besteht hier nur, falls für die entsprechende Zeitschrift/den entsprechenden Sammelband ein Abonnement besteht oder es sich um einen OpenAccess-Titel handelt.

Volltext: https://doi.org/10.3390/diagnostics14090879
 Volltext: https://www.mdpi.com/2075-4418/14/9/879
 DOI: https://doi.org/10.3390/diagnostics14090879
Datenträger:Online-Ressource
Sprache:eng
Sach-SW:cardiovascular imaging
 contrast media
 dual-layer detector CT
 spectral detector CT
 transcatheter aortic valve implantation
 transcatheter aortic valve replacement
K10plus-PPN:1903782449
Verknüpfungen:→ Zeitschrift

Permanenter Link auf diesen Titel (bookmarkfähig):  https://katalog.ub.uni-heidelberg.de/titel/69257396   QR-Code
zum Seitenanfang