Navigation überspringen
Universitätsbibliothek Heidelberg
Status: Bibliographieeintrag

Verfügbarkeit
Standort: ---
Exemplare: ---
heiBIB
 Online-Ressource
Verfasst von:Haag, Florian [VerfasserIn]   i
 Große Hokamp, Nils [VerfasserIn]   i
 Overhoff, Daniel [VerfasserIn]   i
 Dasegowda, Giridhar [VerfasserIn]   i
 Kuru, Mustafa [VerfasserIn]   i
 Nörenberg, Dominik [VerfasserIn]   i
 Schönberg, Stefan [VerfasserIn]   i
 Kalra, Mannudeep K. [VerfasserIn]   i
 Froelich, Matthias F. [VerfasserIn]   i
Titel:Potential of photon counting computed tomography derived spectral reconstructions to reduce beam-hardening artifacts in chest CT
Verf.angabe:Florian Haag, Nils Große Hokamp, Daniel Overhoff, Giridhar Dasegowda, Mustafa Kuru, Dominik Nörenberg, Stefan O. Schoenberg, Mannudeep K. Kalra, Matthias F. Froelich
E-Jahr:2024
Jahr:29 March 2024
Umfang:11 S.
Fussnoten:Gesehen am 28.10.2024
Titel Quelle:Enthalten in: European journal of radiology
Ort Quelle:Amsterdam [u.a.] : Elsevier Science, 1990
Jahr Quelle:2024
Band/Heft Quelle:175(2024), Artikel-ID 111448, Seite 111448-1-111448-11
ISSN Quelle:1872-7727
Abstract:Purpose - Aim of the recent study is to point out a method to optimize quality of CT scans in oncological patients with port systems. This study investigates the potential of photon counting computed tomography (PCCT) for reduction of beam hardening artifacts caused by port-implants in chest imaging by means of spectral reconstructions. - Method - In this retrospective single-center study, 8 ROIs for 19 spectral reconstructions (polyenergetic imaging, monoenergetic reconstructions from 40 to 190 keV as well as iodine maps and virtual non contrast (VNC)) of 49 patients with pectoral port systems undergoing PCCT of the chest for staging of oncologic disease were measured. Mean values and standard deviation (SD) Hounsfield unit measurements of port-chamber associated hypo- and hyperdense artifacts, bilateral muscles and vessels has been carried out. Also, a structured assessment of artifacts and imaging findings was performed by two radiologists. - Results - A significant association of keV with iodine contrast as well as artifact intensity was noted (all p < 0.001). In qualitative assessment, utilization of 120 keV monoenergetic reconstructions could reduce severe and pronounced artifacts completely, as compared to lower keV reconstructions (p < 0.001). Regarding imaging findings, no significant difference between monoenergetic reconstructions was noted (all p > 0.05). In cases with very high iodine concentrations in the subclavian vein, image distortions were noted at 40 keV images (p < 0.01). - Conclusions - The present study demonstrates that PCCT derived spectral reconstructions can be used in oncological imaging of the thorax to reduce port-derived beam-hardening artefacts. When evaluating image data sets within a staging, it can be particularly helpful to consider the 120 keV VMIs, in which the artefacts are comparatively low.
DOI:doi:10.1016/j.ejrad.2024.111448
URL:Bitte beachten Sie: Dies ist ein Bibliographieeintrag. Ein Volltextzugriff für Mitglieder der Universität besteht hier nur, falls für die entsprechende Zeitschrift/den entsprechenden Sammelband ein Abonnement besteht oder es sich um einen OpenAccess-Titel handelt.

Volltext: https://doi.org/10.1016/j.ejrad.2024.111448
 Volltext: https://www.sciencedirect.com/science/article/pii/S0720048X24001645
 DOI: https://doi.org/10.1016/j.ejrad.2024.111448
Datenträger:Online-Ressource
Sprache:eng
Sach-SW:Artifacts
 Photon Counting Computed Tomography
 Port system
 Protocol optimization
 Staging
K10plus-PPN:1907035478
Verknüpfungen:→ Zeitschrift

Permanenter Link auf diesen Titel (bookmarkfähig):  https://katalog.ub.uni-heidelberg.de/titel/69267814   QR-Code
zum Seitenanfang