Navigation überspringen
Universitätsbibliothek Heidelberg
Status: Bibliographieeintrag

Verfügbarkeit
Standort: ---
Exemplare: ---
heiBIB
 Online-Ressource
Verfasst von:Debus, Jürgen [VerfasserIn]   i
 Essig, Marco [VerfasserIn]   i
 Schad, Lothar R. [VerfasserIn]   i
 Wenz, Frederik [VerfasserIn]   i
 Baudendistel, Klaus [VerfasserIn]   i
 Knopp, Michael V. [VerfasserIn]   i
 Engenhart, Rita [VerfasserIn]   i
 Lorenz, Walter Josef [VerfasserIn]   i
Titel:Functional magnetic resonance imaging in a stereotactic setup
Verf.angabe:Jürgen Debus, Marlo Essig, Lothar R. Schad, Frederik Wenz, Klaus Baudendistel, Michael V. Knopp, Rita Engenhart, Walter J. Lorenz
Jahr:1996
Umfang:6 S.
Fussnoten:Elektronische Reproduktion der Druck-Ausgabe 25. März 1999 ; Gesehen am 12.12.2024
Titel Quelle:Enthalten in: Magnetic resonance imaging
Ort Quelle:Amsterdam [u.a.] : Elsevier Science, 1982
Jahr Quelle:1996
Band/Heft Quelle:14(1996), 9, Seite 1007-1012
ISSN Quelle:1873-5894
Abstract:The localization of critical structures within the brain is important for the planning of therapeutic strategies. Functional MRI is capable to assess functional response of cortical structures to certain stimuli. The authors present two techniques for functional MRI (fMRI) in a stereotactic set-up. The skull of the patients has been immobilized for stereotactic treatment planning either with a self developed stereotactic ceramic frame and bony fixation or with an individual precision mask system made of light cast. It has been shown that this frame does not produce any image distortion. fMRI was performed using a modified FLASH sequence on a conventional 1.5 T MRI scanner with a specially developed linear polarized head coil. The imaging technique used was an optimized conventional 2D and 3D, first order flow rephased, gradient echo sequence (FLASH) with fat-suppression and reduce bandwidth (16-28 Hz/pixel) and TR = 80-120 ms, TE = 60 ms, flip angle = 40°, matrix = 128 × 128, FOV = 150-250 mm, slice-thickness = 2-5 mm, NEX = 1, and a total single scan time for one image of about 7 sec. The motor cortex stimulation was achieved by touching each finger to thumb in a sequential, self-paced, and repetitive manner. Statistical parametric maps based on student's test were calculated. Pixels with a highly significant signal increase (p < 0.001) are overlaid on T1w SE images. The primary motor and sensory cortex could be visualized with this method in all 10 patients that were imaged in this study. Due to tight fixation of the patient's skull there have been no motion artifacts. These results show that functional MRI is feasible in an stereotactic set-up with an standard 1.5 T scanner. This is a prerequisite for the exact pre therapeutic assessment of the function of cortical centers.
DOI:doi:10.1016/S0730-725X(96)02108-X
URL:Bitte beachten Sie: Dies ist ein Bibliographieeintrag. Ein Volltextzugriff für Mitglieder der Universität besteht hier nur, falls für die entsprechende Zeitschrift/den entsprechenden Sammelband ein Abonnement besteht oder es sich um einen OpenAccess-Titel handelt.

Volltext: https://doi.org/10.1016/S0730-725X(96)02108-X
 Volltext: https://www.sciencedirect.com/science/article/pii/S0730725X9602108X
 DOI: https://doi.org/10.1016/S0730-725X(96)02108-X
Datenträger:Online-Ressource
Sprache:eng
Sach-SW:Functional imaging
 Magnetic resonance imaging, techniques
 Motor cortex stimulation
 Stereotactic immobilization
 Treatment planning
K10plus-PPN:1912173220
Verknüpfungen:→ Zeitschrift

Permanenter Link auf diesen Titel (bookmarkfähig):  https://katalog.ub.uni-heidelberg.de/titel/69283210   QR-Code
zum Seitenanfang