Navigation überspringen
Universitätsbibliothek Heidelberg
Status: Bibliographieeintrag

Verfügbarkeit
Standort: ---
Exemplare: ---
heiBIB
 Online-Ressource
Verfasst von:Kaatsch, Hanns Leonhard [VerfasserIn]   i
 Fulisch, Florian [VerfasserIn]   i
 Dillinger, Daniel [VerfasserIn]   i
 Kubitscheck, Laura [VerfasserIn]   i
 Becker, Benjamin V [VerfasserIn]   i
 Piechotka, Joel [VerfasserIn]   i
 Brockmann, Marc A [VerfasserIn]   i
 Froelich, Matthias F. [VerfasserIn]   i
 Schönberg, Stefan [VerfasserIn]   i
 Overhoff, Daniel [VerfasserIn]   i
 Waldeck, Stephan [VerfasserIn]   i
Titel:Ultra-low-dose photon-counting CT of paranasal sinus
Titelzusatz:an in vivo comparison of radiation dose and image quality to cone-beam CT
Verf.angabe:Hanns Leonhard Kaatsch, MD, Florian Fulisch, MD, Daniel Dillinger, MD, Laura Kubitscheck, MD, Benjamin V. Becker, MD, Joel Piechotka, MSc, Marc A. Brockmann, MSc, Matthias F. Froelich, MD, Stefan O. Schoenberg, MD, Daniel Overhoff, Stephan Waldeck, MD
E-Jahr:2024
Jahr:February 2024
Umfang:6 S.
Illustrationen:Illustrationen
Fussnoten:Online veröffentlicht: 13. Dezember 2023 ; Gesehen am 15.01.2025
Titel Quelle:Enthalten in: Dentomaxillofacial radiology
Ort Quelle:[Oxford] : Oxford University Press, 1972
Jahr Quelle:2024
Band/Heft Quelle:53(2024), 2 vom: Feb., Seite 103-108
ISSN Quelle:1476-542X
Abstract:This study investigated the differences in subjective and objective image parameters as well as dose exposure of photon-counting CT (PCCT) compared to cone-beam CT (CBCT) in paranasal sinus imaging for the assessment of rhinosinusitis and sinonasal anatomy.This single-centre retrospective study included 100 patients, who underwent either clinically indicated PCCT or CBCT of the paranasal sinus. Two blinded experienced ENT radiologists graded image quality and delineation of specific anatomical structures on a 5-point Likert scale. In addition, contrast-to-noise ratio (CNR) and applied radiation doses were compared among both techniques.Image quality and delineation of bone structures in paranasal sinus PCCT was subjectively rated superior by both readers compared to CBCT (P < .001). CNR was significantly higher for photon-counting CT (P < .001). Mean effective dose for PCCT examinations was significantly lower than for CBCT (0.038 mSv ± 0.009 vs. 0.14 mSv ± 0.011; P < .001).In a performance comparison of PCCT and a modern CBCT scanner in paranasal sinus imaging, we demonstrated that first-use PCCT in clinical routine provides higher subjective image quality accompanied by higher CNR at close to a quarter of the dose exposure compared to CBCT.
DOI:doi:10.1093/dmfr/twad010
URL:Bitte beachten Sie: Dies ist ein Bibliographieeintrag. Ein Volltextzugriff für Mitglieder der Universität besteht hier nur, falls für die entsprechende Zeitschrift/den entsprechenden Sammelband ein Abonnement besteht oder es sich um einen OpenAccess-Titel handelt.

Volltext: https://doi.org/10.1093/dmfr/twad010
 DOI: https://doi.org/10.1093/dmfr/twad010
Datenträger:Online-Ressource
Sprache:eng
K10plus-PPN:1914630076
Verknüpfungen:→ Zeitschrift

Permanenter Link auf diesen Titel (bookmarkfähig):  https://katalog.ub.uni-heidelberg.de/titel/69290903   QR-Code
zum Seitenanfang