Navigation überspringen
Universitätsbibliothek Heidelberg
Status: Bibliographieeintrag

Verfügbarkeit
Standort: ---
Exemplare: ---
heiBIB
 Online-Ressource
Verfasst von:Spiecker, Rebecca [VerfasserIn]   i
 Pfeiffer, Pauline [VerfasserIn]   i
 Biswal, Adyasha [VerfasserIn]   i
 Shcherbinin, Mykola [VerfasserIn]   i
 Spiecker, Martin [VerfasserIn]   i
 Hessdorfer, Holger [VerfasserIn]   i
 Hurst, Mathias [VerfasserIn]   i
 Zharov, Yaroslav [VerfasserIn]   i
 Bellucci, Valerio [VerfasserIn]   i
 Faragó, Tomáš [VerfasserIn]   i
 Zuber, Marcus [VerfasserIn]   i
 Herz, Annette [VerfasserIn]   i
 Cecilia, Angelica [VerfasserIn]   i
 Czyzycki, Mateusz [VerfasserIn]   i
 Dias, Carlos Sato Baraldi [VerfasserIn]   i
 Novikov, Dmitri [VerfasserIn]   i
 Krogmann, Lars [VerfasserIn]   i
 Hamann, Elias [VerfasserIn]   i
 Kamp, Thomas van de [VerfasserIn]   i
 Baumbach, Tilo [VerfasserIn]   i
Titel:Dose-efficient in vivo X-ray phase contrast imaging at micrometer resolution by Bragg magnifiers
Verf.angabe:Rebecca Spiecker, Pauline Pfeiffer, Adyasha Biswal, Mykola Shcherbinin, Martin Spiecker, Holger Hessdorfer, Mathias Hurst, Yaroslav Zharov, Valerio Bellucci, Tomáš Faragó, Marcus Zuber, Annette Herz, Angelica Cecilia, Mateusz Czyzycki, Carlos Sato Baraldi Dias, Dmitri Novikov, Lars Krogmann, Elias Hamann, Thomas van de Kamp, Tilo Baumbach
E-Jahr:2023
Jahr:Dezember 2023
Fussnoten:Gesehen am 15.01.2025 ; Online veröffentlicht: 7. Dezember 2023
Titel Quelle:Enthalten in: Optica
Ort Quelle:Washington, DC : Optica, 2014
Jahr Quelle:2023
Band/Heft Quelle:10(2023), 12 vom: Dez., Seite 1633-1640
ISSN Quelle:2334-2536
Abstract:X-ray imaging enables the study of morphodynamic and physiological processes in living organisms. However, the required photon flux increases with the desired spatial resolution and with it the requirements for dose efficiency. We realize full-field imaging at micrometer resolution close to the highest possible dose efficiency. This is achieved by combining propagation-based phase contrast with Bragg crystal optics and a high-Z single-photon-counting detector, all designed for X-ray energies that allow minimal dose for a given image quality. We prove the superior imaging performance compared to conventional systems and, in particular, show a substantial increase in dose efficiency for high spatial frequencies that comprise the relevant high-resolution components of the image. We demonstrate the potential of the technique by a behavioral in vivo study of submillimeter-sized parasitoid chalcid wasps within their host eggs before and during emergence. The findings show that the technique opens up new possibilities for dose-sensitive studies at micrometer resolution, not only in life sciences but also in materials research.
DOI:doi:10.1364/OPTICA.500978
URL:Bitte beachten Sie: Dies ist ein Bibliographieeintrag. Ein Volltextzugriff für Mitglieder der Universität besteht hier nur, falls für die entsprechende Zeitschrift/den entsprechenden Sammelband ein Abonnement besteht oder es sich um einen OpenAccess-Titel handelt.

kostenfrei: Volltext: https://doi.org/10.1364/OPTICA.500978
 kostenfrei: Volltext: https://opg.optica.org/optica/abstract.cfm?uri=optica-10-12-1633