| Online-Ressource |
Verfasst von: | Spelle, Laurent [VerfasserIn]  |
| Costalat, Vincent [VerfasserIn]  |
| Caroff, Jildaz [VerfasserIn]  |
| Wodarg, Fritz [VerfasserIn]  |
| Fischer, Sebastian [VerfasserIn]  |
| Herbreteau, Denis [VerfasserIn]  |
| Möhlenbruch, Markus Alfred [VerfasserIn]  |
| Januel, Anne-Christine [VerfasserIn]  |
| Papagiannaki, Chrysanthi [VerfasserIn]  |
| Klisch, Joachim [VerfasserIn]  |
| Numminen, Jussi [VerfasserIn]  |
| Rautio, Riitta [VerfasserIn]  |
| Berlis, Ansgar [VerfasserIn]  |
| Mihalea, Cristian [VerfasserIn]  |
| Chalumeau, Vanessa [VerfasserIn]  |
| Downer, Jonathan [VerfasserIn]  |
| Cortese, Jonathan [VerfasserIn]  |
| Ikka, Leon [VerfasserIn]  |
| Gallas, Sophie [VerfasserIn]  |
| Bester, Maxim [VerfasserIn]  |
| Liebig, Thomas [VerfasserIn]  |
| Velasco, Stéphane [VerfasserIn]  |
| Grimaldi, Lamiae [VerfasserIn]  |
| Byrne, James [VerfasserIn]  |
| Szikora, Istvan [VerfasserIn]  |
| Pierot, Laurent [VerfasserIn]  |
| Cognard, Christophe [VerfasserIn]  |
Titel: | CLinical EValuation of WEB 17 device in intracranial aneuRysms (CLEVER) |
Titelzusatz: | 1-year effectiveness results for ruptured and unruptured aneurysms |
Verf.angabe: | Laurent Spelle, Vincent Costalat, Jildaz Caroff, Fritz Wodarg, Sebastian Fischer, Denis Herbreteau, Markus A. Möhlenbruch, Anne-Christine Januel, Chrysanthi Papagiannaki, Joachim Klisch, Jussi Numminen, Riitta Rautio, Ansgar Berlis, Cristian Mihalea, Vanessa Chalumeau, Jonathan Downer, Jonathan Cortese, Leon Ikka, Sophie Gallas, Maxim Bester, Thomas Liebig, Stéphane Velasco, Lamiae Grimaldi, James Byrne, Istvan Szikora, Laurent Pierot, Christophe Cognard |
Jahr: | 2024 |
Umfang: | 5 S. |
Illustrationen: | Illustrationen |
Fussnoten: | Zuerst online veröffentlicht: 11. Juli 2024 ; Gesehen am 17.02.2025 |
Titel Quelle: | Enthalten in: Journal of neuroInterventional surgery |
Ort Quelle: | London : BMJ Journals, 2009 |
Jahr Quelle: | 2024 |
Band/Heft Quelle: | (2024) online ahead of print, Seite 1-5, 5 Seiten |
ISSN Quelle: | 1759-8486 |
Abstract: | Background The Woven EndoBridge (WEB) device is designed to treat wide-necked bifurcation aneurysms. The WEB 17 is the latest iteration and can be delivered through a 0.017″ microcatheter. The CLEVER study demonstrated that WEB 17 is safe and effective for providing protection against bleeding or rebleeding at 1 month and 1 year. - Objective To evaluate angiographic stability at 1 year. - Methods The CLEVER study was a prospective multicenter study conducted in 17 European centers, involved 163 subjects, comprising 60 ruptured and 103 unruptured aneurysms. Independent assessment of 1-year follow-up imaging was incorporated into the study design. - Results Aneurysm diameters ranged from 2.0 to 9.2 mm, with 95.7% being broad-based (dome-to-neck ratio <2). Follow-up imaging at 1 year was completed for 146 out of 163 subjects (89.6%) and evaluated by an independent core laboratory. The primary efficacy endpoint of adequate occlusion without re-treatment at 1 year was achieved for 120 (82.2%) of all subjects. At 1 year, the adequate occlusion rate was 86.5% for ruptured aneurysms (73.1% complete occlusion) and 82.4% for unruptured aneurysms (57.1% complete occlusion). The overall re-treatment rate at 1 year was 2.6% (4/152), with 3.1% (3/97) for unruptured aneurysms and 1.8% (1/55) for ruptured aneurysms - Conclusion Delivery of the WEB 17 via 0.017 inch catheters represents a significant evolution of the WEB design. The results of CLEVER presented here demonstrate that it maintains the same efficacy as previous generations of WEB. |
DOI: | doi:10.1136/jnis-2024-021918 |
URL: | Bitte beachten Sie: Dies ist ein Bibliographieeintrag. Ein Volltextzugriff für Mitglieder der Universität besteht hier nur, falls für die entsprechende Zeitschrift/den entsprechenden Sammelband ein Abonnement besteht oder es sich um einen OpenAccess-Titel handelt.
kostenfrei: Volltext: https://doi.org/10.1136/jnis-2024-021918 |
| kostenfrei: Volltext: https://jnis.bmj.com/content/early/2025/01/26/jnis-2024-021918 |
| DOI: https://doi.org/10.1136/jnis-2024-021918 |