Navigation überspringen
Universitätsbibliothek Heidelberg
Status: Bibliographieeintrag

Verfügbarkeit
Standort: ---
Exemplare: ---
heiBIB
 Online-Ressource
Verfasst von:Görtz, Lukas [VerfasserIn]   i
 Hohenstatt, Sophia [VerfasserIn]   i
 Vollherbst, Dominik [VerfasserIn]   i
 Weyland, Charlotte S. [VerfasserIn]   i
 Nikoubashman, Omid [VerfasserIn]   i
 Gronemann, Christian [VerfasserIn]   i
 Pflaeging, Muriel [VerfasserIn]   i
 Siebert, Eberhard [VerfasserIn]   i
 Bohner, Georg [VerfasserIn]   i
 Zopfs, David [VerfasserIn]   i
 Schlamann, Marc [VerfasserIn]   i
 Liebig, Thomas [VerfasserIn]   i
 Dorn, Franziska [VerfasserIn]   i
 Wiesmann, Martin [VerfasserIn]   i
 Möhlenbruch, Markus Alfred [VerfasserIn]   i
 Kabbasch, Christoph [VerfasserIn]   i
Titel:Safety and efficacy of coated flow diverters in the treatment of cerebral aneurysms during single antiplatelet therapy
Titelzusatz:a multicenter study
Verf.angabe:Lukas Goertz, Sophia Hohenstatt, Dominik F. Vollherbst, Charlotte S. Weyland, Omid Nikoubashman, Christian Gronemann, Muriel Pflaeging, Eberhard Siebert, Georg Bohner, David Zopfs, Marc Schlamann, Thomas Liebig, Franziska Dorn, Martin Wiesmann, Markus A. Möhlenbruch and Christoph Kabbasch
E-Jahr:2024
Jahr:December 2024
Umfang:8 S.
Illustrationen:Illustrationen
Fussnoten:Gesehen am 17.06.2025
Titel Quelle:Enthalten in: Interventional neuroradiology
Ort Quelle:London : Sage Publishing, 1995
Jahr Quelle:2024
Band/Heft Quelle:30(2024), 6 vom: Dez., Seite 819-826
ISSN Quelle:2385-2011
Abstract:Objective - This multicenter study evaluates the safety and efficacy of coated flow diverters (cFDs) for the treatment of cerebral aneurysms under single antiplatelet therapy (SAPT). - Methods - This is a retrospective, observational study of 41 patients (median age: 58 years) with 41 aneurysms (median size: 7 mm, 29 [71%] saccular, 9 [22%] ruptured) treated with cFDs at four neurovascular centers between 2020 and 2023. Scheduled cases received continuous SAPT starting seven days before the procedure. Emergency cases were treated with tirofiban followed by SAPT loading. The safety endpoint was ischemic complications occurring during the procedure and within four months of clinical follow-up. - Results - The Pipeline Vantage or Flex Shield was used in 26 (63%) procedures, the FRED X in 12 (29%), the p48/64 Hydrophilic Polymer Coating in 2 (5%), and the Derivo Embolization Device 2heal in 1 (2%). Single antiplatelet therapy consisted of prasugrel in 27 (66%) patients, ticagrelor in 9 (22%), and ASA in 5 (12%). There were 2 (5%) early ischemic complications (one minor stroke and one transient ischemic attack). There were no late ischemic complications in the four-month follow-up of 35 patients. The six dropouts included four nontreatment-related deaths after subarachnoid hemorrhage and two patients with a poor outcome after subarachnoid hemorrhage. Complete and favorable occlusion rates (median: 7 months) were 75% (27/36) and 89% (32/36), respectively. - Conclusions - Coated flow diverter implantation in the setting of SAPT was safe and effective and warrants confirmation in a prospective comparative trial.
DOI:doi:10.1177/15910199241286542
URL:Bitte beachten Sie: Dies ist ein Bibliographieeintrag. Ein Volltextzugriff für Mitglieder der Universität besteht hier nur, falls für die entsprechende Zeitschrift/den entsprechenden Sammelband ein Abonnement besteht oder es sich um einen OpenAccess-Titel handelt.

Volltext: https://doi.org/10.1177/15910199241286542
 Volltext: https://journals.sagepub.com/doi/10.1177/15910199241286542
 DOI: https://doi.org/10.1177/15910199241286542
Datenträger:Online-Ressource
Sprache:eng
K10plus-PPN:1928493823
Verknüpfungen:→ Zeitschrift

Permanenter Link auf diesen Titel (bookmarkfähig):  https://katalog.ub.uni-heidelberg.de/titel/69357137   QR-Code
zum Seitenanfang