Navigation überspringen
Universitätsbibliothek Heidelberg
Status: Bibliographieeintrag

Verfügbarkeit
Standort: ---
Exemplare: ---
heiBIB
 Online-Ressource
Verfasst von:Licht, Christian [VerfasserIn]   i
 Ilicak, Efe [VerfasserIn]   i
 Boada, Fernando E. [VerfasserIn]   i
 Guye, Maxime [VerfasserIn]   i
 Zöllner, Frank G. [VerfasserIn]   i
 Schad, Lothar R. [VerfasserIn]   i
 Rapacchi, Stanislas [VerfasserIn]   i
Titel:A noise-robust post-processing pipeline for accelerated phase-cycled 23Na Multi-Quantum Coherences MRI
Verf.angabe:Christian Licht, Efe Ilicak, Fernando E. Boada, Maxime Guye, Frank G. Zöllner, Lothar R. Schad, Stanislas Rapacchi
E-Jahr:2025
Jahr:February 2025
Umfang:11 S.
Illustrationen:Illustrationen, Diagramme
Fussnoten:Im Titel ist die Zahl 23 hochgestellt ; Online verfügbar: 22. Januar 2025, Artikelversion: 26. Februar 2025 ; Gesehen am 15.07.2025
Titel Quelle:Enthalten in: Zeitschrift für medizinische Physik
Ort Quelle:Amsterdam [u.a.] : Elsevier, 1990
Jahr Quelle:2025
Band/Heft Quelle:35(2025), 1 vom: Feb., Seite 98-108
ISSN Quelle:1876-4436
Abstract:Purpose - To develop an improved post-processing pipeline for noise-robust accelerated phase-cycled Cartesian Single (SQ) and Triple Quantum (TQ) sodium (23Na) Magnetic Resonance Imaging (MRI) of in vivo human brain at 7 T. - Theory and Methods - Our pipeline aims to tackle the challenges of 23Na Multi-Quantum Coherences (MQC) MRI including low Signal-to-Noise Ratio (SNR) and time-consuming Radiofrequency (RF) phase-cycling. Our method combines low-rank k-space denoising for SNR enhancement with Dynamic Mode Decomposition (DMD) to robustly separate SQ and TQ signal components. This separation is crucial for computing the TQ/SQ ratio, a key parameter of 23Na MQC MRI. We validated our pipeline in silico, in vitro and in vivo in healthy volunteers, comparing it with conventional denoising and Fourier transform (FT) methods. Additionally, we assessed its robustness through ablation experiments simulating a corrupted RF phase-cycle step. - Results - Our denoising algorithm doubled SNR compared to non-denoised images and enhanced SNR by up to 29% compared to Wavelet denoising. The low-rank approach produced high-quality images even at later echo times, allowing reduced signal averaging. DMD effectively separated the SQ and TQ signals, even with missing RF phase cycle steps, resulting in superior Structural Similarity (SSIM) of 0.89±0.024 and lower Root Mean Squared Error (RMSE) of 0.055±0.008 compared to conventional FT methods (SSIM=0.71±0.061, RMSE=0.144±0.036). This pipeline enabled high-quality 8x8x15mm3 in vivo 23Na MQC MRI, with a reduction in acquisition time from 48 to 10min at 7 T. - Conclusion - The proposed pipeline improves robustness in 23Na MQC MRI by exploiting low-rank properties to denoise signals and DMD to effectively separate SQ and TQ signals. This approach ensures high-quality MR images of both SQ and TQ components, even in accelerated and incomplete RF phase-cycling cases.
DOI:doi:10.1016/j.zemedi.2024.12.004
URL:Bitte beachten Sie: Dies ist ein Bibliographieeintrag. Ein Volltextzugriff für Mitglieder der Universität besteht hier nur, falls für die entsprechende Zeitschrift/den entsprechenden Sammelband ein Abonnement besteht oder es sich um einen OpenAccess-Titel handelt.

kostenfrei: Volltext: https://doi.org/10.1016/j.zemedi.2024.12.004
 kostenfrei: Volltext: https://www.sciencedirect.com/science/article/pii/S093938892400117X
 DOI: https://doi.org/10.1016/j.zemedi.2024.12.004
Datenträger:Online-Ressource
Sprache:eng
Sach-SW:Dynamic mode decomposition
 Low-rank
 Neuroimaging
 Single and triple quantum imaging
 Sodium MRI
 Sodium multi-quantum coherences
K10plus-PPN:1930477791
Verknüpfungen:→ Zeitschrift

Permanenter Link auf diesen Titel (bookmarkfähig):  https://katalog.ub.uni-heidelberg.de/titel/69365632   QR-Code
zum Seitenanfang