Navigation überspringen
Universitätsbibliothek Heidelberg
Status: Bibliographieeintrag

Verfügbarkeit
Standort: ---
Exemplare: ---
heiBIB
 Online-Ressource
Verfasst von:El-Battrawy, Ibrahim [VerfasserIn]   i
 Beiert, Thomas [VerfasserIn]   i
 Koepsel, Katharina [VerfasserIn]   i
 Kovacs, Boldizsar [VerfasserIn]   i
 Dreher, Tobias C. [VerfasserIn]   i
 Blockhaus, Christian [VerfasserIn]   i
 Tenbrink, David [VerfasserIn]   i
 Klein, Norbert [VerfasserIn]   i
 Kuntz, Thomas [VerfasserIn]   i
 Lapp, Hendrik [VerfasserIn]   i
 Shin, Dong-In [VerfasserIn]   i
 Abumayyaleh, Mohammad S. A. [VerfasserIn]   i
 Saguner, Ardan Muammer [VerfasserIn]   i
 Hijazi, Mido [VerfasserIn]   i
 Erath, Julia W. [VerfasserIn]   i
 Duru, Firat [VerfasserIn]   i
 Mügge, Andreas [VerfasserIn]   i
 Akın, Ibrahim [VerfasserIn]   i
 Aweimer, Assem [VerfasserIn]   i
Titel:Wearable cardioverter defibrillator after ICD-system explantation
Titelzusatz:data from a multicenter registry
Verf.angabe:Ibrahim El-Battrawy, Thomas Beiert, Katharina Koepsel, Boldizsar Kovacs, Tobias C. Dreher, Christian Blockhaus, David Tenbrink, Norbert Klein, Thomas Kuntz, Hendrik Lapp, Dong-In Shin, Mohammad Abumayyaleh, Ardan Muammer Saguner, Mido Hijazi, Julia W. Erath, Firat Duru, Andreas Mügge, Ibrahim Akin & Assem Aweimer
E-Jahr:2025
Jahr:01 March 2025
Umfang:7 S.
Illustrationen:Illustrationen
Fussnoten:Gesehen am 23.07.2025
Titel Quelle:Enthalten in: Scientific reports
Ort Quelle:[London] : Springer Nature, 2011
Jahr Quelle:2025
Band/Heft Quelle:15(2025), 1, Artikel-ID 7270, Seite 1-7
ISSN Quelle:2045-2322
Abstract:Data on the use of the wearable cardioverter defibrillator (WCD) among patients after cardiac implantable electronic device explantation of 1- to 3-chamber implantable cardioverter defibrillator systems (ICD) are sparse. Accordingly, several guidelines give a different recommendation regarding WCD indication in this cohort. We aimed to study the baseline characteristics and outcome of patients treated with WCD after ICD explantation. The primary outcome is appropriate WCD shock. Within a multicenter registry 109 patients received a WCD to bridge the time after ICD-system explantation until reimplantation due to a persistent ICD-indication. The mean follow-up was 824 ± 773 days. In addition to ventricular tachyarrhythmias and/or WCD shocks during WCD wear time, also the rate of rehospitalization for ventricular tachyarrhythmias, atrial fibrillation, stroke and congestive heart failure after ICD-reimplantation was evaluated. Patients had a mean age of 65 ± 14 years, and were hospitalized for 21 ± 15 days. The index left ventricular ejection fraction (LVEF) was at baseline 35.7 ± 14.1% and 35.7 ± 14.2% at short-term follow-up. Mean wear time of the WCD was 61 ± 46 days after ICD-system explantation. During that time an appropriate WCD shock was documented in 7.3% of patients. Up to 80.6% of patients after ICD-system explantation were re-implanted. The rates of rehospitalization due to ventricular tachyarrhythmias, heart failure and atrial fibrillation were 7.3%, 6.8% and 4.1%, respectively. After ICD-reimplantation the rate of appropriate shocks was 12/89 (13.4%). Occurrence of malignant ventricular tachyarrythmia after ICD-system explantation is high and the use of WCD among these patients could be beneficial in preventing sudden cardiac death.
DOI:doi:10.1038/s41598-025-91046-4
URL:Bitte beachten Sie: Dies ist ein Bibliographieeintrag. Ein Volltextzugriff für Mitglieder der Universität besteht hier nur, falls für die entsprechende Zeitschrift/den entsprechenden Sammelband ein Abonnement besteht oder es sich um einen OpenAccess-Titel handelt.

kostenfrei: Volltext: https://doi.org/10.1038/s41598-025-91046-4
 kostenfrei: Volltext: https://www.nature.com/articles/s41598-025-91046-4
 DOI: https://doi.org/10.1038/s41598-025-91046-4
Datenträger:Online-Ressource
Sprache:eng
Sach-SW:Cardiology
 Medical research
K10plus-PPN:1931573107
Verknüpfungen:→ Zeitschrift

Permanenter Link auf diesen Titel (bookmarkfähig):  https://katalog.ub.uni-heidelberg.de/titel/69368110   QR-Code
zum Seitenanfang