Navigation überspringen
Universitätsbibliothek Heidelberg
Status: Bibliographieeintrag

Verfügbarkeit
Standort: ---
Exemplare: ---
heiBIB
 Online-Ressource
Titel:Construction and performance of a silicon photomultiplier/extruded scintillator tail-catcher and muon-tracker
Mitwirkende:Adloff, Catherine [VerfasserIn]   i
 Eckert, Patrick [VerfasserIn]   i
 Kaplan, Alexander [VerfasserIn]   i
 Schultz-Coulon, Hans-Christian [VerfasserIn]   i
 Shen, Wei [VerfasserIn]   i
 Stamen, Rainer [VerfasserIn]   i
 Tadday, Klaus Alexander [VerfasserIn]   i
Körperschaft:CALICE Collaboration [VerfasserIn]   i
Verf.angabe:CALICE Collaboration: C. Adloff, P. Eckert, A. Kaplan, H.-C. Schultz-Coulon, W. Shen, R. Stamen, A. Tadday [und weitere]
E-Jahr:2012
Jahr:April 27, 2012
Umfang:26 S.
Fussnoten:Gesehen am 22.11.2018
Titel Quelle:Enthalten in: Journal of Instrumentation
Ort Quelle:London : Inst. of Physics, 2006
Jahr Quelle:2012
Band/Heft Quelle:7(2012,04) Artikel-Nummer P04015, 26 Seiten
ISSN Quelle:1748-0221
Abstract:A prototype module for an International Linear Collider (ILC) detector was built, installed, and tested between 2006 and 2009 at CERN and Fermilab as part of the CALICE test beam program, in order to study the possibilities of extending energy sampling behind a hadronic calorimeter and to study the possibilities of providing muon tracking. The “tail catcher/muon tracker” (TCMT) is composed of 320 extruded scintillator strips (dimensions 1000 × 50 × 5 mm 3 ) packaged in 16 one-meter square planes interleaved between steel plates. The scintillator strips were read out with wavelength shifting fibers and silicon photomultipliers. The planes were arranged with alternating horizontal and vertical strip orientations. Data were collected for muons and pions in the energy range 6 GeV to 80 GeV. Utilizing data taken in 2006, this paper describes the design and construction of the TCMT, performance characteristics, and a beam-based evaluation of the ability of the TCMT to improve hadronic energy resolution in a prototype ILC detector. For a typical configuration of an ILC detector with a coil situated outside a calorimeter system with a thickness of 5.5 nuclear interaction lengths, a TCMT would improve relative energy resolution by 6-16% for pions between 20 and 80 GeV.
DOI:doi:10.1088/1748-0221/7/04/P04015
URL:Bitte beachten Sie: Dies ist ein Bibliographieeintrag. Ein Volltextzugriff für Mitglieder der Universität besteht hier nur, falls für die entsprechende Zeitschrift/den entsprechenden Sammelband ein Abonnement besteht oder es sich um einen OpenAccess-Titel handelt.

Volltext: http://dx.doi.org/10.1088/1748-0221/7/04/P04015
 Volltext: http://stacks.iop.org/1748-0221/7/i=04/a=P04015
 DOI: https://doi.org/10.1088/1748-0221/7/04/P04015
Datenträger:Online-Ressource
Sprache:eng
K10plus-PPN:1572201169
Verknüpfungen:→ Zeitschrift

Permanenter Link auf diesen Titel (bookmarkfähig):  https://katalog.ub.uni-heidelberg.de/titel/68245123   QR-Code
zum Seitenanfang